Starting a Local Management Session

After you have powered on the switch and waited two minutes for it to
initialize its management software, start a local management session
using the Console port on the management panel, as explained in this
section.
Note
The initial management session must be from the Console port.
To start a local management session, perform the following procedure:
1. Connect the RJ-45 end of the management card included with the
switch to the Console RS-232 port on the management panel. Refer to
Figure 41.
Figure 41. Connecting the Management Cable to the Console RS-232 Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
personal computer with a terminal emulation program.
3. Configure the VT-100 terminal or terminal emulation program as
follows:
Default baud rate: 9600 bps (The baud rates of the Console port
are 9600, 19200, 38400, 57600, and 115200 bps.)
Data bits: 8
Parity: None
Stop bits: 1
Flow controller: None
x220 Series Installation Guide