During an adjustment session all parameters may be reset to their factory values in the following way :
PARAMETERS
OPERATIONS
FACTORY
Press the SETUP key (19), then press the NUMBER key 9.
VALUES
All the parameters (except the access code) are reset to the factory values.
FACTORY VALUES :
If you do not have a remote control, you can only adjust the sensitivity parameter, by means of the push buttons + and - .
SENSITIVITY
CONFIGURATION
WITH PUSH
BUTTONS
The factory default values (except the factory value of the access code) may be restored by pressing the two push buttons together for
at least two seconds.

LED SIGNAL

SYMPTOM
TROUBLE-
The door will not open and no red LED
SHOOTING
lights up.
The door opens and closes constantly.
The door will not close.
Red LED OFF
The X-MTF mode is not functioning
correctly.
The sensor stays in detection
permanently when X-MFT is activated.
Parameter
Sensitivity
Hold time
X-MTF Sensitivity
Detection mode
Immunity
Mounting height
Output configuration
Door control
+ : press to increase the sensitivity by one unit
- : press to decrease the sensitivity by one unit
The LED flashes for a few seconds after the power-on, and flashes during the
configuration with the remote control.
The LED lights up when the sensor detects motion.
PROBABLE CAUSE
The sensor power is off.
The door control is set to level 3.
The sensor "sees" the door
moving.
When closing the door creates
vibrations picked up by the sensor.
On-Off switch at door control in
wrong position or is faulty
Improper output configuration on
the sensor.
The sensor detects motion in the
detection zone.
Note: When X-MTF mode is
activated the detection zone is
slightly bigger.
Factory Values Table
Values
0 - 9
0 - 9
0 - 9
1 - 5
1 - 3
1 - 2
1 - 2
1 - 3
CORRECTIVE ACTION
Check the wiring and the power supply.
Set door control to automatic mode (level 1).
Increase the tilt angle and/or reduce the sensitivity
and/or increase the immunity.
Ensure that the sensor is correctly fixed.
Switch to unidirectional mode.
Increase the immunity.
Reduce the sensitivity.
Check to insure On-Off switch for door is in the ON or
AUTOMATIC position.
Check the output configuration setting on each
sensor connected to the door operator.
Cut and restore power supply.
Step out of the detection field and wait for about ten
seconds. The sensor has to take a new reference.
Check whether there are moving objects in the
detection zone or decrease the X-MTF sensitivity and
increase the hold time.
Factory setting
7
0
0
2
2
1
1
1
6/8

Advertisement