MECHANICAL
CONFIGURATION
A.
B.
C.
D.
Note: All the sensing fields correspond to the following adjustments:
• Bidirectional mode (detection mode: 1)
• X-MTF deactivated
• Hold time: 0.5 s
DIMENSIONS OF THE SENSING FIELD (WIDTH, DEPTH, UNCOVERED ZONE) ARE DETERMINED BY THE
SENSITIVITY SETTING (0 to 9)
The sensing fields correspond to the following adjustments:
• Vertical angle of antenna: 30°
• Mounting height: 2.2 m
DIMENSIONS OF THE SENSING FIELD (WIDTH, DEPTH, UNCOVERED ZONE) ARE DETERMINED BY THE
MOUNTING HEIGHT
The sensing fields correspond to the following adjustments:
• Vertical angle of antenna: 30°
• Sensitivity: 9
For a mounting height from 3 m, set the sensor in "high mounting" mode
(only in appropriate areas).
POSITION OF THE SENSING FIELD IS DETERMINED BY THE LATERAL ANGLE OF THE PLANAR ANTENNA
POSITION OF THE SENSING FIELD IS DETERMINED BY THE VERTICAL ANGLE OF THE ANTENNA
The sensing fields correspond to the following adjustments:
• Mounting height: 2.2 m
• Sensitivity: 9
To obtain a sensing field as close to
the door as possible, set the antenna
at its minimum tilt angle (0° to 15°).
To obtain a sensing field close to the
door, set the antenna at a tilt angle of
30°.
To obtain a sensing field distant from
the door, set the antenna at a tilt
angle of 45°.
FOR A CEILING MOUNTING:
The sensing fields correspond to the following adjustments:
• Mounting height: 2.2 m
• Sensitivity: 9
The sensing fields correspond to the
following adjustments:
• Lateral angle of antenna: 30°, -30°
• Mounting height: 2.2 m
Example of
deep-field operator
application.
Example of standard
operator application.
Example of standard
operator application
(with uncovered
zone).
3/8

Advertisement