CrimeStopper EZEE Start EZ-45DP Installation Instructions Manual page 24

Remote engine starting system
Hide thumbs Also See for EZEE Start EZ-45DP:
Table of Contents

Advertisement

OPTIONS PROGRAMMING Cont.
17. OEM Disarm / Unlock Pulse:
Some vehicles like Nissan and VW require a shorter setting to prevent the vehicle from attempting to roll down the
windows due to the length of the UNLOCK and/or DISARM pulses. Use this option to SHORTEN the Disarm/Unlock
Pulses should your vehicle require this. Symptom: Windows will slightly vent or begin to roll down when unlocking.
18. Pre-Set Starter Cranking Time: (Requires Option #15 to be set to "Timed Crank")
This option controls the starter output cranking time. Choices are 0.5, 0.75, 1, or 1.5 seconds.
19. Diesel Glow Plug Delay:
This option controls the system's Diesel vehicle interface. Using this option you can control whether the unit monitors the
vehicle's glow plug circuit using the Pink input wire (Default), or you may select a specific delay time before cranking. This
option is helpful if you are unable to locate a glow plug signal. Just select a delay time and do not connect the Pink Glow
Plug wire. Selections: 10, 20, 30 seconds, or Monitor Pink Wire (Default).
20. Remote Start Run Time:
This option controls the engine run time for remote start. Use the buttons on the remote control to set a choice of 12, 24,
36, or 48 minutes. The default setting is 24 minutes.
21. Smart Tachless Voltage Adjustment:
This option controls the voltage reference point when using smart Tachless mode. Pressing the Lock or Unlock buttons
on the remote raises or lowers the reference level in 1% increments from 79%-100%. Button #3 resets the unit to the
factory default reference point of 93%. The default 93% setting works for most vehicles. See page 15 for additional
Smart Tachless mode information.
22. Aux #2:
This option controls the function of the Blue/Black wire for a negative output for a Momentary, Pulse, Timed or
Latched output, depending on option used. Option #23 controls the length of time output.
23. Aux #2 Time control: (1 sec. to 255 sec.) Default = 12 seconds
This option determines to length of output time of Aux #2 (Blue/Black wire). Pressing the Lock or Unlock buttons on the
remote raises or lowers the time by one second.
24. Option Reset:
(RESTORE TO DEFAULT FOR EZ-45DP ONLY)
on pages 20-21
This option allows you to restore all programmable options to factory default values. Go to the option 24 and press the
Unlock Button #2 on the remote. The lights flash 2 times and all values will be reset to factory original settings.
24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ezee start ez-55dpEzee start ez-95fm

Table of Contents