PROGRAMMABLE OPTIONS
10. DISARM WITH TRUNK POP (AUX. OUTPUT 1)
Controls whether the system will or will not DISARM when the trunk pop or AUX. feature is used. When the feature
is turned on the unit will DISARM when opening trunk or using an auxiliary device controlled by the Gray wire.
11. 10/60 Sec. OPEN DOOR WARNING
This setting changes the delay time in which the alarm system begins to monitor the Door circuit. This option can
prevent the alarm from giving warning chirps on vehicles with a delayed dome light.
12. DOOR LOCK/UNLOCK PULSE TIME
This option controls the amount of time (0.75 sec. or 3 sec.) for the lock/unlock pulse. The standard pulse time for
most vehicles is 0.75 Sec. The 3 sec. setting may be required for Mid 1980's through Mid 1990's European
Vehicles that require a long lock and unlock pulse to operate Vacuum door lock systems.
13. DOUBLE UNLOCK PULSE
With this option ON, the unit will send 2 unlock pulses when the system is disarmed. This feature may be required
for interfacing a Factory alarm or keyless entry system.
14. LOCK DURING/AFTER REMOTE START
This option controls whether the unit will automatically lock during and after a remote Start abort or time-out.
15. NO OPTION / NOT USED
16. TIMED CRANK or TACH MONITOR MODE
This option controls whether the system uses a tach wire to control the starter or uses a pre-set cranking time.
17. PRE-SET STARTER CRANKING TIME: (Requires Option #16 in "Timed Crank" Setting)
This option controls the starter output cranking time when "Timed Crank" Mode is turned on. Choices are 0.5, 0.75,
1.25, or 1.5 seconds.
18. DIESEL GLOW PLUG DELAY
This option controls the system's Diesel vehicle interface. Using this option you can control whether the unit
monitors the vehicle's glow plug circuit using the Pink input wire (Default), or you may select a specific delay time
before cranking. This option is helpful if you are unable to locate a glow plug signal. Just select a delay time and do
not connect the Pink Glow Plug wire. Selections: 10, 20, 30 seconds, or Monitor Pink Wire (Default).
19. REMOTE START ENGINE RUN TIME
Set engine run time for remote start for 12, 24, 36 or 48 minutes as desired.