If no connection is established, the message 'NOT LINKED' is displayed and the parent unit
,
starts to beep.
What to do if no link is established
-
If the parent unit is out of range, place it closer to the baby unit.
-
If the baby or parent unit is too close to another DECT appliance (e.g. a cordless phone),
switch off this appliance or move the unit away from this appliance.
-
If the baby unit is switched off, switch it on.

operating range

-
The operating range is 330 meters/1000 feet outdoors and up to 50 meters/150 feet indoors.
-
The operating range of the baby monitor varies depending on the surroundings and factors that
cause interference. Wet and moist materials cause so much interference that the range loss is up
to 100%. For interference from dry materials, see table below
Dry materials
Wood, plaster, cardboard, glass
(without metal, wires or lead)
Brick, plywood
Reinforced concrete
Metal grilles or bars
Metal or aluminum sheets
Functions and feedback on the baby unit
nightlight
The nightlight produces a soft glow that comforts your baby.
1
Press the Q button on the baby unit to switch on the nightlight.
2
Press the Q button again to switch off the nightlight.

lullaby function

1
Press the K button on the baby unit to play the last selected lullaby. (Fig. 2)
The selected lullaby repeats for 15 minutes.
,
2
Press the
button to select another lullaby from the list. (Fig. 3)
3
To adjust the sound level of the lullaby, press the volume + or the volume – button on the
baby unit (Fig. 4).
Note: You can only set the loudspeaker volume on the baby unit when a lullaby is playing. If you set the volume
for the lullaby higher, the sound will also be louder when you use the talk function on the parent unit.
4
To stop lullaby playing, press the K button on the baby unit.
paging the parent unit
If you have lost the parent unit, you can use the FIND button on the baby unit to locate the parent
unit. This function only works when the parent unit is switched on.
1
Press FIND on the baby unit and the parent unit produces a paging alert tone (Fig. 5).
2
To stop the paging alert tone, press FIND on the baby unit again or press any button on the
parent unit. The paging alert tone stops automatically after 2 minutes.
Material thickness
< 30cm (12in)
< 30cm (12in)
< 30cm (12in)
< 1cm (0.4in)
< 1cm (0.4in)
EngliSh
Loss of range
0-10%
5-35%
30-100%
90-100%
100%