Starting The Engine; Connecting Electrical Loads - Champion 46553 Owner's Manual & Operating Instructions

4000 starting watts / 3000 max rated watts 2850 continuous use watts
Table of Contents

Advertisement

46553
ENGLISH

Starting the Engine

1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator.
Never start or stop the generator with electrical
devices plugged in or turned on.
3. Turn the fuel valve to the "ON" position.
4. Flip the ignition switch to the "ON" position.
5. Move the choke lever to the "CHOKE" position.
6. RECOIL START: Pull the starter cord slowly until
resistance is felt and then pull rapidly
7. Do not over-choke. As as soon as engine starts, move
the choke lever to the "RUN" position.
NOTE
Keep choke lever in "Choke" position for only 1
pull of the recoil starter. After first pull, move choke
lever to the "Run" position for up to the next 3
pulls of the recoil starter. Too much choke leads to
sparkplug fouling/engine flooding due to the lack of
incoming air. This will cause the engine not to start.
NOTE
If the engine starts but does not run make certain
that the generator is on a flat, level surface. The
engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level
falls below a critical threshold.

Connecting Electrical Loads

1. Let the engine stabilize and warm up for a few
minutes after starting
2. Plug in and turn on the desired 120 Volt AC single
phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT connect 50 Hz loads to the generator.
– DO NOT overload the generator.
NOTE
Connecting a generator to your electric utility
company's power lines or to another power source
may be against the law. In addition this action,
if done incorrectly, could damage your generator
and appliances and could cause serious injury or
even death to you or a utility worker who may be
working on nearby power lines. If you plan to run a
portable electric generator during an outage, please
notify your electric utility company immediately
and remember to plug your appliances directly
into the generator. Do not plug the generator into
any electric outlet in your home. Doing so could
create a connection to the utility company power
lines. You are responsible for ensuring that your
generator's electricity does not feed back into the
electric utility power lines.
If the generator will be connected to a building
electrical system, consult your local utility company
or a qualified electrician. Connections must isolate
generator power from utility power and must comply
with all applicable laws and codes.
OPERATION
10
REV 46553-20130301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents