Page 1
PORTABLE GENERATOR yEAR MODEL NUMBER 46561 LIMITED WARRANTY 10006 Santa Fe Springs Road SAvE THESE INSTRuCTIONS Santa Fe Springs CA 90670 Important Safety Instructions USA / 1 (877) 338-0999 MADE IN CHINA are included in this manual. REV 46561-20111117 www.championpowerequipment.com...
Page 2
Have questions or need assistance? Do not return this product to the store! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Product Info & Updates • Tech Bulletins • Frequently Asked Questions • Product Registration –...
ENGLISH INTROduCTION Introduction Accessories Congratulations on your purchase of a Champion Champion Power Equipment manufactures and sells Power Equipment generator . CPE designs and builds accessories designed to help you get the most from generators to strict specifications . With proper use and your purchase .
. Please call our help line at 1 (877) 338-0999 situation which, if not avoided, could result in death or serious injury . CAuTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury . REV 46561-20111117...
Keep hands and feet away from rotating parts . combustible materials . Tie up long hair and remove jewelry . Operate equipment with guards in place . DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught . REV 46561-20111117...
Page 7
A spark arrestor may be required . The operator should contact local fire agencies for laws or – Electrical output is lost – Equipment sparks, smokes or emits flames regulations relating to fire prevention requirements . – Equipment vibrates excessively REV 46561-20111117...
DC to the electric starter and receiver control supply fuel to the engine . module . Air Cleaner – Protects the engine by filtering dust Power Panel – See “Power Panel” section . and debris from the intake air . REV 46561-20111117...
Ground Terminal – Consult an electrician for local push-to-reset circuit breaker . Use each recepticle grounding regulations . to operate 120 Volt AC, single phase, 60 Hz loads requiring up to 20 Amp 0r 2400 Watts of power . REV 46561-20111117...
(6) times . The RCM controls the Auto Choke during each attempt to start . If the generator does not start, call Champion Customer Care team for assistance at 1 (877) 338-0999 . To stop the generator by Remote Control, press the “STOP”...
2 . Slide the M10x105 wheel bolt through the washer, sleeve and wheel . 3 . Slide the bolt through the mount point on the frame . 4 . Fasten securely with the M10 nut . 5 . Repeat steps 2-4 to attach the second wheel . REV 46561-20111117...
. 4 . Check engine oil level daily and add as needed . CAuTION The engine is equipped with a low-oil-shutoff and will stop when the oil level in the crankcase falls below the threshold level . REV 46561-20111117...
DO NOT fill fuel tank indoors . DO NOT fill fuel tank when the engine is running or hot . DO NOT overfill the fuel tank . DO NOT light cigarettes or smoke when filling the fuel tank . REV 46561-20111117...
If the generator will be connected to a building electrical system, consult your local utility company or a qualified electrician . Connections must isolate generator power from utility power and must comply with all applicable laws and codes . REV 46561-20111117...
5 . Squeeze in a clean, absorbent cloth to remove all management facility . excess oil . 6 . Place the fi lter in the assembly . 7 . Reattach the air fi lter cover and snap in place . REV 46561-20111117...
Contact our help line at 1 (877) 338-0999 to locate the 4 . Carefully remove the carbon deposits from the spark nearest Champion Power Equipment certified service arrester screen with a wire brush . dealer for your generator or engine maintenance needs .
. Crank the engine slowly to distribute the oil and lubricate the cylinder . 9 . Reattach the spark plug . 10 . Store the unit in a clean, dry place out of direct sunlight . REV 46561-20111117...
– Increase the separation between the equipment and receiver . – Connect the equipment into an outlet on a circuit different from that to which the receiver is connected . Consult the dealer or an experienced radio/TV technician for help . REV 46561-20111117...
Management” Faulty cords or device Check for damaged, bare or frayed wires . Replace defective device for further technical support: Technical Service Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1 (877) 338-0999 tech@championpowerequipment .com REV 46561-20111117...
. Warranty Qualifications Other Exclusions Champion Power Equipment (CPE) will register this This warranty excludes: warranty upon receipt of your Warranty Registration Card – Cosmetic defects such as paint, decals, etc .
States Environment Protection Agency (u.S. EPA.) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with U .S . EPA emission regulations . yOuR WARRANTy RIGHTS ANd OBLIGATIONS: The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 1997 and later small off-road engine .
Page 30
ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim . CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part . REV 46561-20111117...
Page 31
Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc . to sell and service that CPE product during his normal business hours . Claims for repair or adjustment found to be caused solely by defects in material or workmanship will not be denied because the engine was not properly maintained and used .