4000 Starting Watts / 3500 Rated Watts Recoil Start PORTABLE GENERATOR MODEL NUMBER 46598 10006 Santa Fe Springs Road SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 Important Safety Instructions USA / 1-877-338-0999 MADE IN CHINA are included in this manual. REV 46598-20130614 www.championpowerequipment.com...
Page 2
AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods.
Introduction Accessories Congratulations on your purchase of a Champion Champion Power Equipment manufactures and sells Power Equipment generator. CPE designs and builds accessories designed to help you get the most from your generators to strict specifications. With proper use and purchase.
Please call our help line at 1-877-338-0999. situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. REV 46598-20130614...
Inform your electricity provider immediately if you or anyone in your household depends on electrical euipment to live. Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency. REV 46598-20130614...
Page 7
– Electrical output is lost – Equipment sparks, smokes or emits flames A spark arrestor may be required. The operator – Equipment vibrates excessively should contact local fire agencies for laws or regulations relating to fire prevention requirements. REV 46598-20130614...
Oil Filler Cap – Check and fill engine oil level. Fuel Valve – Used to turn fuel supply on and off to Power Panel – See “Power Panel” section. engine. Air Filter – Protects the engine by filtering dust and debris from the intake air. REV 46598-20130614...
(NEMA L14-30R) – May be used to supply 60 Hz electrical loads. electrical power for the operation of 120/240 Volt AC, 30 Amp, single phase 60 Hz electrical loads. Ground Terminal – Consult an electrician for local grounding regulations. REV 46598-20130614...
1. Place the generator on a flat, level surface. 2. Remove oil fill cap/dipstick to add oil. 3. Add up to 0.63 qt. (0.6 L) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL. REV 46598-20130614...
We strongly recommend that you consult with a qualified fuel tank. electrician to ensure compliance with local electrical codes. WARNING Pouring fuel too fast through the fuel screen may result in blow back of fuel at the operator while filling. REV 46598-20130614...
During operation the muffler and exhaust fumes produced will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or contained, temperatures can become extremely heated and may lead to fire. REV 46598-20130614...
– DO NOT overload the generator. is not in use. NOTE If the engine will not be used for a period of two (2) weeks or longer, please see the Storage section for proper engine and fuel storage. REV 46598-20130614...
To alleviate high altitude issues other than the natural calculated in step 2. Surge wattage is the extra power loss, Champion Power Equipment can provide a burst of power needed to start some electric driven high altitude carburetor main jet. The alternative main equipment.
5. Squeeze in a clean, absorbent cloth to remove all 6. Dispose of used oil at an approved waste management facility. excess oil. 6. Place the filter in the assembly. 7. Reattach the air filter cover and snap in place. REV 46598-20130614...
Service your generator more frequently when operating in adverse conditions. Contact our helpline at 1-877-338-0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs. Every 8 hours or daily Check oil level...
9. Remove the spark plug and pour about 1⁄2 ounce of oil into the cylinder. Crank the engine slowly to distribute the oil and lubricate the cylinder. 10. Reattach the spark plug. 11. Store the unit in a clean, dry place out of direct sunlight. REV 46598-20130614...
– Fuel Capacity ....3.8 gal. (14.4 L) Your Champion Power Equipment product is designed and rated for continuous operation at ambient – Gross Weight ....
Review load and adjust. See “Power Management” Faulty cords or device Check for damaged, bare or frayed wires. Replace defective device for further technical support: Technical Service Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1-877-338-0999 tech@championpowerequipment.com REV 46598-20130614...
Warranty Qualifications Other Exclusions Champion Power Equipment (CPE) will register this This warranty excludes: warranty upon receipt of your Warranty Registration Card – Cosmetic defects such as paint, decals, etc.
Page 27
United States Environment Protection Agency (U.S. EPA) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations. YOUR WARRANTY RIGHTS AND OBLIGATIONS: The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2013 small off-road engine and engine powered equipment.
Page 28
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines. The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 29
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.