Crestron C2N-VEQ4 Operation Manual page 22

Cresnet 4-channel digital volume control
Hide thumbs Also See for C2N-VEQ4:
Table of Contents

Advertisement

Cresnet 4-Channel Digital Volume Control
C2N-VEQ4 General Audio Controls Symbol Input Descriptions
Signal Type
Digital
Analog
18 • Cresnet 4-Channel Digital Volume Control: C2N-VEQ4
Name
MuteOut (1 through 4)
plus MuteAll
VolOut (1 through 4)
TrebOut (1 through 4)
BassOut (1 through 4)
Mixer Controls – Slot 9, SubSlot 2
The 4x4 matrix mixer controls provide the equivalent of a small-scale mixing board.
These controls use a logarithmic scale (0dB to –80dB) with 0dB corresponding to 0
attenuation; anything –80dB and below will mute the signal. The C2N-VEQ4 expects
values ranging from 0d to –800d (and lower), 0.1dB per count, to appear at each
output. (Refer to the signal description table on the next page.) You can direct any
input or combination of inputs to any output, via analog variables in the SIMPL
program.
NOTE: Mixer controls are not accessible in an X-Generation system.
C2N-VEQ4 Mixer Controls Symbol
Crestron C2N-VEQ4
Value
Definition
1/0
High = Mute On
Low = Mute Off
0 to 100%
0% = Volume set to lowest
-80dB to +20dB
100% = Volume set to Highest
0 to 100%
50%=Flat Treble
± 15dB
0%= -15dB — 100%= +15dB
0 to 100%
50%=Flat Bass
± 15dB
0%= -15dB — 100%= +15dB
Operations Guide - DOC. 6135A