Operation
7.1 Operation with Android
Use the "Identification" function to check whether you are connected with the required
connectivity module.
Procedure
1. Open the "SIDRIVE IQ Config" application.
2. Open the overview page.
3. Select an asset from the "Visible" tab.
4. Tap on the motor symbol
The connectivity module LED flashes. The firmware version is read out and displayed.
7.1.3

Changing measurement and synchronization intervals

The following intervals are preset in the factory:
• 5 minutes - interval for measuring temperature, vibrations, rotational frequency, operating
status
You can change these settings within a specified range.
• 15 minutes - interval for calculation of speed, torque and energy consumption
This setting is always three times the short measurement interval that has been set.
• 24 hours - interval for transmission of the stored data to SIDRIVE IQ Fleet
You can change these settings within a specified range of between 1 and 48 hours.
Note
Effects that influence the battery life
Shorter intervals result in a shorter battery life.