4. Hardware Configurations
Power Distribution Unit
Power Distribution Unit
There are two sizes for power distribution units: 1U and 2U.
A power distribution unit is an option to connect power supply units to power outlets when power sockets are
limited.
■
Power Distribution Unit (AC8A/200V, 1U, 4 Outlets)
There are four outlets and two inlets.
Figure 116
Power Distribution Unit (AC8A/200V, 1U, 4 Outlets)
1
Main line switch
This turns on and off the power distribution unit.
2
Outlet (OUTPUT)
This is a socket (IEC60320 C13) for outgoing power supply. This socket is used to connect a power cord (AC
output cable).
3
Inlet (INPUT)
This is a socket (IEC60320 C14) for incoming power supply. This socket is used to connect a power cord (AC
input cable).
The specifications of a power distribution unit and the power cords that are provided are shown below.
Table 63
Power Distribution Unit (AC8A/200V, 1U, 4 Outlets) and Provided Power Cord Specifications
Item
Power
Input cable
1
2
3
Voltage
Phase
Frequency
Connection type
Length
Quantity
171
Specifications
AC 200 – 240V
Single
50Hz/60Hz
IEC60320 C13 n NEMA L6-15P
3m
2
Design Guide