Setup

To avoid tip over, make sure cart is on a flat and level
surface. Failure to do so could result in injury or
equipment damage.
1. Check packing nut (D). Fill with Throat Seal Liquid
(TSL). Torque to 25 ft-lb (34 N•m).
D
2. Attach electrically conductive fluid hose to pump
lower outlet via outlet check valve and tighten.
Attaching the hose directly to the lower pump can
result in damage to the sprayer during cavitation, or
when the sprayer runs out of material. Use an outlet
check valve between the lower pump and hose to
avoid damage.
333208F
NOTICE
The minimum hose size allowable is 3/8 in. ID x 50 ft
(10 mm x 15 m). Smaller hoses can cause high
pressure spikes and result in damage to the sprayer.
3. Attach hose to gun and tighten.
4. Attach material supply inlet hose to pump lower.
NOTE: Maximum suggested length is 6 ft (1.8 m),
minimum suggested inner diameter is 1 in. (2.5 cm).
5. Pull pressure adjustment knob (H) out and turn
counterclockwise until it stops. Push the knob in to
lock.
6. Turn power switch (E) OFF. Connect unit to power
source. See F
. 3, page 6.
IG
7. Always flush and prime sprayer before each use
(see page 11).
NOTICE
H
ti20171a_1
Setup
9