Repair
6. Remove clip (11) and slide coupling cover (13) up to
remove coupling (12).
11
7. Use a wrench to hold tie rod flats to keep rods (8) from
turning. Unscrew nuts (10) and remove lower (9).
10
9
20
13
12
8
8. Refer to Xtreme Lower manual (311762) to service
lower.
9. Reconnect lower by following disconnect steps in
reverse order.
NOTE: Torque nuts (10) to 50-60 ft-lb (68-81 N•m).