Spray; Shutdown - Graco e-Xtreme Z25 Operation - Repair - Parts

Electric high pressure airless sprayer
Table of Contents

Advertisement

Spray

Spray
Do not allow pump to run dry. It will quickly accelerate
to a high speed causing damage.
1. Perform Prime procedure, page 11.
2. Perform Pressure Relief Procedure, page 10.
3. Install tip and tip guard onto gun.
4. Turn power switch (E) ON.
5. Pull out and turn pressure adjustment knob (H) until
desired pressure is reached. Turn clockwise to
increase pressure, counterclockwise to decrease
pressure. Push knob in to lock.
12
NOTICE
E
H
ti20171a_1
6. Disengage gun trigger lock.
7. Spray a test pattern. Read fluid manufacturer's
recommendations. Adjust as necessary.
8. Flush when finished spraying. See Prime/Flush,
page 11.
9. Perform Pressure Relief Procedure, page 10.

Shutdown

Never leave water or water-based fluid in pump over
night. If water-base fluid has been used, flush with
water first, then with a rust inhibitor (such as mineral
spirits). Relieve pressure, but leave rust inhibitor in
pump to protect parts from corrosion.
To shutdown, perform Prime/Flush procedure, page 11.
Perform Pressure Relief Procedure, page 10.
ti5048b
NOTICE
333208F

Advertisement

Table of Contents
loading