AudioCodes Mediant 1000 Hardware Installation Manual page 63

And e-sbc
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

CHAPTER 5    Cabling the Device
(French) Avertissements:
(Japanese) ご注 意
本 製 品 に添 付 の電 源 ケーブルは、 Mediant 1000B Gateway & E-SBC に専 用 設 計 さ れ
ているため、 汎 用 性 があり ません. 本 電 源 ケーブルを他 の機 器 に使 用 さ れないよう 、 ご注
意 く ださ い.
For dual power supply:
➢ To connect the device to the power supply:
On the device's rear panel, connect the left (active) 100-240V~50-60 Hz power socket to a
standard electrical outlet using the supplied AC power cord.
Units must be connected (by service personnel) to a socket-outlet with a
protective earthing connection.
Use only the AC power cord supplied with the device.
When using only one Power Supply module, the second AC power socket on the
rear panel is covered by a plastic sticker. Please do not remove the sticker and
connect anything to this power socket. Remove the sticker only when two Power
Supply modules are used.
L'appareil doit être branché à une prise murale à condition qu'elle soit mise à la
masse.
Utilisez uniquement le cordon AC fourni avec l'appareil.
Connect each Power Supply module to a different AC supply circuit.
The two AC power sources must have the same ground potential.
Configure the device to send an SNMP alarm (acPowerSupplyAlarm) upon a
failure or removal of any of the installed Power Supply modules. For enabling this
functionality, use the [Mediant1000DualPowerSupplySupported] parameter. For
more information, refer to the
Figure 5-24: Connecting to AC Power Supply
Mediant 1000 Gateway & E-SBC | Hardware Installation Manual
User's
Manual.
- 55 -

Advertisement

Table of Contents
loading