AudioCodes Mediant 1000 Hardware Installation Manual page 29

And e-sbc
Hide thumbs Also See for Mediant 1000:
Table of Contents

Advertisement

CHAPTER 3    Physical Description
Item
1
2
3
4
5
Figure 3-13: OSN4B Module LEDs
Table 3-16: OSN4B Module LEDs Description
Color
State
Green
Flashing
Solid
Red
On
-
Off
Green
Solid
Flashing
-
Off
Orange
On
Green
On
-
Off
Blue
Flashing
Mediant 1000 Gateway & E-SBC | Hardware Installation Manual
Description
Firmware (BIOS) application active, payload (x86) in
sleep.
Firmware (BIOS) application active, payload (x86)
active.
Out-of-service indicator due to hardware failure.
Normal operation.
Valid Ethernet link (cable connection) established.
Activity in the link.
The LED goes temporarily off if network packets are
sent or received. When this LED remains off, a valid
link has not been established due to a missing or a
faulty cable connection.
1000Base-TX connection.
100Base-T connection.
10Base-T connection if LED #3 is active.
Module undergoing shutdown sequence when handle
is pulled out to first extraction position, or module had
been inserted and handle is still in first extraction
position
- 21 -