Bosch Conettix DX4020 Installation Manual

Network interface module

Advertisement

Conettix DX4020
Installation Guide
Network Interface
EN
Module

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Conettix DX4020

  • Page 1 Conettix DX4020 Installation Guide Network Interface Module...
  • Page 2: Table Of Contents

    Conettix DX4020 | Installation Guide | Contents Contents Introduction ................................ 4 Overview ................................4 Installation................................5 Mounting................................5 Wiring..................................5 DIP Switch Settings ............................7 GV2 Series, G Series, and 9000 Series Control Panels ..................7 DS7240V2, DS7220V2, and Easy Series V3+ (ICP-EZM2) Control Panels ..........7 DS7400Xi Control Panel.............................
  • Page 3 Conettix DX4020 | Installation Guide | Trademarks Certifications and Approvals Trademarks UL Standards • ® ® Microsoft and Windows are either registered • UL294, Access Control Systems Units trademarks or trademarks of Microsoft • UL864, UL Commercial Fire Alarm signaling Corporation in the United States and/or other •...
  • Page 4: Introduction

    Conettix DX4020 | Installation Guide | 1.0 Introduction 1.0 Introduction 2.0 Overview Use the Conettix DX4020 Ethernet Network Interface Refer to Figure 2 for general system connections. The Module (Figure 1) for bi-directional communications main components are: over Ethernet networks. Generally, you use the •...
  • Page 5: Installation

    Conettix DX4020 | Installation Guide | 3.0 Installation Wiring 3.0 Installation Run the wiring connections from the DX4020 data bus terminals to the compatible control panel’s data bus Inform the operator and the local authority terminals (Figure 4). Refer to the associated control having jurisdiction (AHJ) before installing panel documentation for complete wiring instructions.
  • Page 6 Conettix DX4020 | Installation Guide | 3.0 Installation Figure 5 shows an example of wiring the DX4020 to a control panel. Figure 5: Wiring the DX4020 to a Control Panel 43489F LEDs Off When Normal Charging Status Low Battery - 12.1 VDC...
  • Page 7: Dip Switch Settings

    Conettix DX4020 | Installation Guide | 4.0 DIP Switch Settings Figure 7: DIP Switch Setting for Address 88 4.0 DIP Switch Settings Use the DIP switch settings in Sections 4.1 through 4.4 for the DX4020 network communication. GV2 Series, G Series, and 9000...
  • Page 8: Ds7400Xi Control Panel

    Conettix DX4020 | Installation Guide | 5.0 LEDs DS7400Xi Control Panel 5.0 LEDs Use Option Bus Addresses 13 and 14 (Figure 9 and Figure 10) to send reports. Use Option Bus Address 13 Ethernet and Serial to connect to the RPS for remote programming.
  • Page 9: Xport

    Conettix DX4020 | Installation Guide | 6.0 IP Address Programming Factory-Programmed IP XPort Configuration Figure 13 and Table 4 identify and describe the DX4020’s two bi-color LEDs that are built into the The DX4020 is shipped with the following default IP front of the XPort connector.
  • Page 10: Assigning The Initial Ip Address

    Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 6.4.2 Using the ARP Command Assigning the Initial IP Address 1. From the Start Menu, select Start Run to open Before proceeding, read this entire section. a DOS window. Ensure that the DX4020 has power and the 2.
  • Page 11: Using Telnet To Complete Configuration

    Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 6. Click Connect and wait a few seconds for the Using Telnet to Complete following failed message to appear. Configuration Refer to Section 6.5.1 Using Windows 98 Telnet when using Windows 98.
  • Page 12 Conettix DX4020 | Installation Guide | 6.0 IP Address Programming If you press [Enter] within 5 sec. of seeing the 12. Press [0] then [Enter] to set up the basic Server “Press Enter to go into Setup Mode” message, the configuration.
  • Page 13 Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 17. Press [Enter] after entering the correct number of Keep your password in a secure place. If bits for the Netmask. you forget or lose the password, you cannot use Telnet again to configure the DX4020...
  • Page 14 Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 26. Press [Enter] four times to specify 0.0.0.0 for 24. Press [Enter] to accept CC as the default remote IP address. ConnectMode. If CC is not the default, type cc and press [Enter] to change it.
  • Page 15: Using Windows 2000/Xp Telnet

    Conettix DX4020 | Installation Guide | 6.0 IP Address Programming 35. At the Main Menu, select 9 to save and close the 4. At the Microsoft Telnet> prompt, type open telnet session. (space) IP ADRESS (space) PORT NUMBER, The following message appears.
  • Page 16: Control Panel Programming

    Conettix DX4020 | Installation Guide | 7.0 Control Panel Programming 7.0 Control Panel Programming Table 7 lists available documentation for DX4020 to control panel programming. Table 7: Compatible Control Panel Documentation Control Panel Documentation D9412GV2/D7412GV2 D9412GV2/D7412GV2 Program Entry Guide (P/N: F01U003636)
  • Page 17 Conettix DX4020 | Installation Guide | 8.0 Specifications Notes Bosch Security Systems, Inc. | 1/09 | F01U045288-05...
  • Page 18 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 (800) 289-0096 © 2009 Bosch Security Systems F01U045288-05...

Table of Contents