5. Installation

This section describes the procedure for the
installation and starting of the pump. It describes
how the work must be carried out and features
requiring special attention.
The installation and starting of the pump may
be carried out only by suitable approved
personnel.
5.1 General
The pump should preferably be installed on a
concrete surface and screwed into place using
the holes of the base. The pump must be
installed in a dry location. If the pump is installed
in a damp location, adequate ventilation must be
ensured to prevent the formation of condensation.
Adequate ventilation must always be ensured to
allow proper operation of motor.
Sufficient space should be allowed for the
installation and maintenance of the pump. Note
the pump dimensions and allow at least 25cm
free space around the unit.
The pump should be installed as close as
possible to the pool for maximum performance.
Ensure
that
the
regulations for proper installation.
Short, straight pipes should be used wherever
possible to avoid frictional losses.
5.2 Power supply
Electric power supply should have the following
characteristics:
Offer a differential protection.
Typical Installation
From Pool
Main Pump
installation
meets
Filter
Offer voltage and frequency values
compliant
the motor
Offer a power not below the value
indicated on
Be equipped with an appropriate thermal
protection.
Be equipped with a thermal relay
adjusted
absorbed.
Be equipped with a cut-off switch with
protective fuses.
Be equipped with cables with a section
suitable to the power absorbed by the
motor.
5.3 Installation
All installation operations should be
performed while the electropump is
disconnected from the mains.
Danger
Do
environments containing gases and/or
inflammable or explosive materials.
Warning
Electropumps are designed so that all
the
local
inoffensive by means of protections.
Do not use the electropump if these
Danger
protections have been removed or are
damaged, since this could cause
serious accidents to people.
The
always have a differential circuit
breaker.
Danger
Boost-Rite
Cleaner
Heater
5
with the values indicated on
nameplate.
the motor nameplate.
according to the actual current
not
install
the
machine
moving
parts
are
machine
supply
line
Return
Chlorinator
in
rendered
should