Page 1
Pump Installation and Service Manual S4S/SB4S Submersible Sewage Pump S4S Shown NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system. Part # 5625-321-1 Item # E-03-321 04/09...
Pumps Operating Two pumps operate together only General in Storage: if sump level rises to the third or Information override float. The override float Pumps with carbon ceramic seals also brings on the second pump in must have impellers manually case of failure of the first pump.
Hydromatic electrical equipment to self-drain the discharge line to Pump is installed in a weatherproof prevent freezing. This can be done Installation enclosure. electrical only with short discharge lines. equipment includes a main circuit Otherwise water will return to the breaker each pump,...
Page 4
changed at any time by loosening Some engineers as described Pump the snubber and readjusting previously prefer to have the Installation cord length. alarm control set below the override control. In either simplex or duplex system the lower or turn-off float based on the distance and pump is set just above the top of volute Making Electrical Connections:...
each wire as sometimes a high Field Service on Motor: Pump leg will exist. One leg can be All submersible motors can be Operations somewhat higher (5 to 10%) serviced (out of warranty) in the without causing trouble. For field by any reliable motor excessive voltage draw on one service shop.
Page 6
should show ground is the 6. Use bearing puller to remove Pump green power lead. bearings. Replace with new Maintenance bearings. Press only on inner 11.Refill the motor chamber face bearing when with oil. Use only high replacing. Pressing on outer grade transformer 6.
Pump runs but will not shut off direction without much noise Pump or vibration. 1. Pump may be air locked. Turn Troubleshooting pump off and let set for 4. Discharge head may be too several minutes, then restart. high. Check total head with gauge when pump...
S4S/SB4S Parts List ORDERING REPLACEMENT PARTS: Product improvements are made from time to time. The latest part design will be furnished as long as it is interchangeable with the old part.When ordering replacement parts, always furnish the following information: (1) pump serial number, (2) pump model and size, (3) part description, (4) part number, (5) impeller diameter (if ordering impeller), (6) quantity required, and (7) shipping instructions.
STANDARD LIMITED WARRANTY HYDROMATIC ® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Hydromatic or 18 months from the manufacturing date, whichever occurs first - provided that such products are used compliance with the requirements of the Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive free non-corrosive liquids.
START-UP REPORT Distributor______________________________________________________Order #: _________________ Installing Contractor: _____________________________________ Phone: _________________________ Sales Contact: __________________________________________ Phone: _________________________ Customer & Location _____________________________________________________________________ SYSTEM INFORMATION A. Size of wet well: __________________________________ Manufacturer:_____________________ B. Discharge from bottom of basin: ___________________ Location: __________________________ C. Inlet from bottom of basin:________________________ Location: __________________________ D.