Pentair MYERS S40HT Series Installation, Operation & Parts Manual

Pentair MYERS S40HT Series Installation, Operation & Parts Manual

Submersible high temperature effluent pumps
Hide thumbs Also See for MYERS S40HT Series:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

SAFETY INFORMATION
Carefully read and follow all safety instructions in this
manual or on pump.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual, look for one
of the following signal words and be alert to the potential for
personal injury!
warns about hazards that will cause serious
personal injury, death or major property damage if ignored.
warns about hazards that can cause serious
personal injury, death or major property damage if ignored.
warns about hazards that will or can cause
minor personal injury or property damage if ignored.
The word NOTICE indicates special instructions which are
important but not related to hazards.
1. Read these rules and instructions carefully. Failure
to follow them could cause serious bodily injury and/or
property damage.
2. Check your local codes before installing. You must
comply with their rules.
3. Vent sewage or septic tank according to local codes.
4. Do not install pump in any location classified as
hazardous by National Electrical Code, ANSI/NFPA
80-1984 or the Canadian Electrical Code.
Hazardous voltage. Can shock,
burn, or kill. During operation the pump is in water.
To avoid fatal shocks, proceed as follows if pump needs
servicing:
5A. Disconnect power to outlet box before unplugging pump.
5B. Take extreme care when changing fuses. Do not stand
in water or put your finger in the fuse socket.
5C. Do not modify the cord and plug. When using the cord
and plug, plug into a grounded outlet only. When wiring
to a system control, connect the pump ground lead to
the system ground.
MOTOR, SWITCH, & CORD SPECIFICATIONS
Model
Motor
Number
HP
Voltage
S40HT-11P
1/3
115/1
S40HT-11
1/3
115/1
S50HTPC1*
1/2
115/1
*Control panel required
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM
PH: 888-987-8677
© 2017 Pentair, plc. All Rights Reserved.
INSTALLATION, OPERATION & PARTS MANUAL
6. Do not run the pump dry. Dry running can overheat the
7. The pump normally runs hot. To avoid burns when
8. The pump is permanently lubricated. No oiling or
DESCRIPTION
These submersible high temperature sump/effluent pumps are
designed for effluent and wastewater removal, sump drainage,
dewatering, flood control. They can be used in boiler blow
down pits, condensate pits and as hot water pumps. Units
have built in thermal overload protection with automatic reset.
The mechanical seal and ball bearings on the motor shaft are
permanently lubricated. Stainless steel hardware and a heavy
duty lift out ring allow for easy disassembly after extended use.
NOTICE: This unit is not designed for applications involving
salt water or brine! Use with salt water or brine will void
warranty.
SPECIFICATIONS
Power supply required .............. See "Motor, Switch and Cord
Maximum Liquid Temperature ............................ 194°F(90°C)
Discharge Adapter ................................ 1-1/2" NPT (S40HT)
California Proposition 65 Warning
chemicals known to the State of California to cause cancer,
birth defects or other reproductive harm.
Motor
Individual
Full
Branch Circuit
Load Amps
Required (Amps)
13.0
15
13.0
15
12.0
15
S40HT & S50HT Series
Submersible High Temperature
Effluent Pumps
pump, (causing burns to anyone handling it) and will
void the warranty.
servicing pump, allow it to cool for 20 minutes after shut-
down before handling it.
greasing is required in normal operation. For overhaul,
see instructions under "Service".
Specifications" chart below
...................................... 2" NPT (S50HT)
This product and related accessories contain
Switch Setting
Cord
in inches (mm)
Length
in ft. (m)
On
20 (6.1)
13.5 (343)
20 (6.1)
20 (6.1)
17.8 (452)
Discharge
Adapter
Off
Size
4.5 (114)
1-1/2"
1-1/2"
8.8 (224)
2"
MY504 (Rev. 10/31/17)

Advertisement

Table of Contents
loading

Summary of Contents for Pentair MYERS S40HT Series

  • Page 1 S40HT-11 115/1 13.0 20 (6.1) – – 1-1/2" S50HTPC1* 115/1 12.0 20 (6.1) 17.8 (452) 8.8 (224) 2" *Control panel required 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 MY504 (Rev. 10/31/17) © 2017 Pentair, plc. All Rights Reserved.
  • Page 2: Installation

    PERFORMANCE 5. DO NOT remove the grounding prong from the plug or modify the plug. To protect against electrical shock, GPM AT TOTAL FEET the power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug the pump into a 3-wire, Model No flow at height shown...
  • Page 3: Pump Disassembly

    SERVICE Green Wire Either Black Wire (connected between General the two tallest Short Divider dividers) Hazardous voltage and risk of cord damage. Can shock, burn, or kill. Before removing the pump from the basin for service, always disconnect electrical power to the pump and the control switch.
  • Page 4 Slide ceramic Pump Disassembly Impeller side of seal plate part onto S40HT Series Permatex Press seal shaft. Pump Disassembly here into cavity Oil Fill Plug Power Cord Housing O-Ring Capscrew Insulating Lower Disk Motor Figure Housing Rotor/Stator Assembly 2. Reinstall motor and shaft to seal plate using the four Shaft Seal, Stator through bolts removed in step 9 under “Disassembly”.
  • Page 5: Repair Parts List

    S40HT SERIES EXPLODED VIEW 411 0895 EC3 REPAIR PARTS LIST Part S40HT-11P S40HT-11 Description Qty. 1/3 HP 115 V 1/3 HP 115 V Power Cord PW117-226-TSE PW117-106-TSE Cord Connector PS17-46P — Handle Ring U97-128 U97-128 1/4" NPT Plug U78-57DT U78-57DT Upper Motor Housing PW18-22F PW18-22...
  • Page 6 MODEL S50HTPC1 REPAIR PARTS Power Cord Assembly Rope Handle Ring 27633B000 U97-102SS Capscrew, U30-539SS Oil Fill Plug U78-57DV Float Switch Cord Clamp, CC0030-13 Motor Assembly PW218-137 Motor Cover PW18-54E 1/4" Hex Capscrew (4) U30-883SS Float Switch PW17-1580B Capscrew, 1/4-20 x 1" Soc Hd.
  • Page 7 TROUBLES-REMEDIES Sudden Starts. If the power is on to the pump when thermal overload resets, the pump may start without warning. If you are working on the pump, you may get an electrical shock or the impeller may catch fingers or tools. Disconnect the power before servicing the pump.
  • Page 8: Limited Warranty

    Limited Warranty Myers warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from ® defects in material and workmanship for the Warranty Period shown below. Warranty Period Product whichever occurs first: Jet pumps, small centrifugal pumps, submersible pumps and 12 months from date of original installation, related accessories...
  • Page 9: Caractéristiques

    20 (6,1) – – 1-1/2 po S50HTPC1* 115/1 12.0 20 (6.1) 17.8 (452) 8.8 (224) 2 po *Tableau de commande nécessaire 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.FEMYERS.COM PH: 888-987-8677 MY504 (Rev. 10/31/17) © 2017 Pentair, plc. All Rights Reserved.
  • Page 10 RENDEMENT électriques, le cordon électrique à 3 conducteurs est muni d'une fiche à 3 broches dont une de mise à la terre. Brancher la pompe dans une prise de courant à 3 trous dont un de mise à la Gal/min (L/min) à la hauteur totale de refoulement en pieds (m) terre et ceci conformément au National Electric Code, au Code Modèles canadien de l'électricité...
  • Page 11: Entretien

    ENTRETIEN Green Wire Fil vert (branché Either Black Wire Un des deux fils noirs entre les deux (connected between Généralités plus grandes the two tallest Short Divider Séparation courte séparations) dividers) Tension dangereuse et risque que le cordon électrique soit endommagé. Risque de secousses, de brûlures, voire de mort.
  • Page 12 Slide ceramic Démontage de la pompe Côté impulseur de la plaque d'étanchéité Impeller side of seal plate part onto Permatex Press seal Permatex Enfoncer le joint shaft. Série S40HT here into cavity dans la cavité Pump Disassembly Bouchon de Oil Fill remplissage Cordon Plug...
  • Page 13: Liste Des Pièces De Rechange

    VUE ÉCLATÉE - SÉRIE S40HT 411 0895 EC3 LISTE DES PIÈCES DE RECHANGE S40HT-11P 1/3 S40HT 1/3 ch Réf. Désignation Qté ch 115 V 115 V Cordon électrique PW117-226-TSE PW117-106-TSE Connecteur du cordon électrique PS17-46P – Anneau de levage U97-128 U97-128 Bouchon fileté...
  • Page 14 PIÈCES DÉTACHÉES DU MODÈLE S50HTPC1 Anneau de préhension Power Cord Assembly Rope Handle Ring Cordon électrique de la corde 27633B000 U97-102SS Capscrew, U30-539SS Vis d’assemblage U30-539SS Bouchon de Oil Fill Plug remplissage d’huile U78-57DV Float Switch Collier du câble de l’interrupteur Cord Clamp, CC0030-13 Motor Assembly flotteur CC0030-13...
  • Page 15: Guide De Recherche Des Pannes

    GUIDE DE RECHERCHE DES PANNES Démarrage soudain. Si le courant alimente la pompe lorsque le dispositif de protection contre les surcharges thermiques se réenclenche, la pompe risque de démarrer sans avertissement. Si, à ce moment-là, on intervient sur la pompe, on risque de subir des secousses électriques ou bien de se coincer les doigts dans l'impulseur ou bien des outils risquent de se coincer dans l'impulseur.
  • Page 16: Garantie Limitée

    Garantie Limitée Myers® garantit à l’acheteur-utilisateur initial (« l’acheteur » ou « vous ») des produits figurant ci-dessous qu’ils seront exempts de tout défaut de matériel et de fabrication pour la période de garantie indiquée ci-dessous. Produit Période de garantie du produit selon la première éventualité...

This manual is also suitable for:

Myers s50ht seriesS40ht seriesS50ht seriesS40ht-11pS40ht-11S50htpc1

Table of Contents