Maintenance/Repair; Disposal - Pentair STA-RITE Boost-Rite S4P100M Manual

Pump for pressure-side cleaners or water boosting applications
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Noisy Pump:
Air leak in Suction line
Debris in plumbing lines or pump housing
Diameter of suction line is too small
Incorrect pump installation
Cavitation (restriction of water)
Heating of Motor:
Insufficient ventilation for motor
Size of wiring too small
8. Maintenance
Disconnect the machine from the mains before
carrying out any maintenance work.
Regular maintenance, cleaning and inspection
of the pumps is extremely important. This will
reduce problems and increase operating safety
and reliability.
8.1 Maintenance
Maintenance of the product should be carried out
only by specially qualified personnel.
Before the starting the pump after extended non-
use or when restarting in the spring, it is
advisable to turn the motor shaft, with the pump
switched off and the pump full of water, by means
of the motor fan using a screwdriver. This will free
the shaft seal and make starting the pump easier.
8.2 Replacement Parts
Replacement parts must conform to the technical
requirements specified by the manufacturer. This
is
always guaranteed when using original
replacement parts. We only offer a guarantee for
original replacement parts supplied by us. We
accept no liability or guarantee in the event of
damage caused by the use of unauthorized
replacement parts or accessories.

9. Disposal

Ensure
disposal of the product which meets
applicable national regulations.
8
safe
and
environmental

Advertisement

Table of Contents
loading

Table of Contents