ALARM
11.0
CLEARING / RESETING THE ALARM
When error occurs, the controller will signal an alarm automatically with audible sound. Pressing <Start> button will stop
audible alarm sound. Press <Start> button again after troubleshooting. If the error has been resolved or can be ignored, the
computer will go back to "open" or "close" or "locked" status. Or else the controller will alarm again.
11.1
ALARM INFORMATION AND TROUBLESHOOTING
NO.
ALARM NAME
#1
DoorStat Error
#3
Over shock
#5
Emergency Stop
#6
Door Pin Err
#7
Inverter error
#9
Error level sensor
#10
Temp sensor of water
Temp sensor of
#11
inverter
#14
Overtime of fill
#15
Overtime of heat
#16
Overtime of drain
#17
Lubrication time
#18
Invt comm overtime
#19
Inv com err
#20
PUNP inverter error
#21
High temp of invt
#33
PUNP inverter alarm
#34
Clear lint of invt
#49
Bkbd comm overtime
#50
Bkbd com err
#51
Parameter error
#52
Program error
#53
Controller failure
®/™ ©2021 Unity Laundry Systems. All rights reserved.
Please check the door switch or door pin
Please check if the load in the machine is too small or too large
Please check Emergency stop is released
Please check door pin or Lock release cord
Please check the inverter, or check the input of inverter
Have not adjusted the level sensor, please contact Unity at 1-800-484-3013
Please check temperature sensor of water
Please check temperature sensor of inverter
Can't reach the set level in time. Please check the fill valve, or check the level sensor
Can't reach the set temperature in time. Please check the device of heat, or check the temperature sensor
There is remaining water in drum. Please check the drain valve
The times of run can be browsed and be cleared by pressing [START] button for 3 seconds from startup
screen
Unable to receive replay data from inverter. Please check power inverter or the parameter of the inverter
Please check electrical connection and ground
Please contact Unity at 1-800-484-3013
Clean lint inside machine and check the inverter fan
Please contact Unity at 1-800-484-3013
Clean lint inside machine and check the inverter fan
Unable to receive replay data from I/0 Board. Please check the wiring between HMI and I/0 Board
Please check electrical connection and ground.
Please contact Unity at 1-800-484-3013
Please contact Unity at 1-800-484-3013
Please contact Unity at 1-800-484-3013