Test Limit Failure

Table 10
shows a cable test that fails because of near end cross talk (NEXT).
Item
The Product detected the Remote ID, and the wire map passed.
The wire map passes because:
The cable can support 10BASE-T (10), 100BASE-TX (100), and 1000BASE-T (1G)
data rate throughputs. The cable cannot support 2.5BASE-T (2.5G) data rate
throughput. The test fails because the test limit is set to verify the cable can
support a 2.5BASE-T (2.5G) data rate throughput.
20
1.800.561.8187
Table 10. NEXT Failure
1
2
3
NEXT
The wires are all connected correctly on both the near and far ends for a
straight through cable. Allow Crossover can be On or Off to test a straight
through cable.
The continuity of the shield is not included as part of the test (Shield > Off).