SICK FLOWSIC600-XT Operating Instructions Manual

SICK FLOWSIC600-XT Operating Instructions Manual

Ultrasonic gas flow meter
Hide thumbs Also See for FLOWSIC600-XT:
Table of Contents

Advertisement

Quick Links

Title Page
FLOWSIC600-XT
Ultrasonic Gas Flow Meter
Installation
Operation
Maintenance
O P E R A T I N G I N S T R U C T I O N S

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLOWSIC600-XT and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK FLOWSIC600-XT

  • Page 1 Title Page O P E R A T I N G I N S T R U C T I O N S FLOWSIC600-XT Ultrasonic Gas Flow Meter Installation Operation Maintenance...
  • Page 2 Legal Information gas factor Subject to change without notice. Real time clock © SICK Engineering GmbH. All rights reserved. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 3 Risk or hazardous situation which could result in severe personal injury or death. CAUTION Hazard or unsafe practice which could result in less severe or minor injuries. NOTICE Hazard which could result in property damage. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 4: Table Of Contents

    ............17 2.2.4.1 Correction in FLOWSIC600-XT electronics ....... . 18 2.2.4.2 Correction outside the FLOWSIC600-XT electronics (volume converter) .
  • Page 5 3.4.2 General connection of the FLOWSIC600-XT ....... . . 63 Criteria for electrical connection .
  • Page 6 Checking the data archives (data logs) ....... . . 103 5.2.6 Creating and evaluating the Diagnostics Comparison report ....103 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 7 Cleaning the FLOWSIC600-XT ........
  • Page 8 Cont ents FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 9: Important Information

    Important information FLOWSIC600-XT Important information About this document Important safety information Intended use Responsibility of user FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 10: About This Document

    These Operating Instructions cover standard applications which conform with the technical data specified. Additional information and assistance for special applications are available from your SICK representative. It is generally recommended to take advantage of qualified consulting services provided by SICK experts for your specific application.
  • Page 11: Hazard Through Electromagnetic Interference

    The FLOWSIC600-XT measuring system is used for measuring the actual volumetric flow rate of gases transported in pipelines. Apart from that, the FLOWSIC600-XT can also deter- mine the actual corrected volume and the sound velocity. Separate meters are available to determine the gas volume depending on the flow direction.
  • Page 12: Operation In Potentially Explosive Atmospheres

    European Directive 2014/68/EC for pressure equip- ment. Restrictions of use 1.3.5 Check the FLOWSIC600-XT is suitably equipped for your application (e.g., gas conditions). NOTICE: ▸ The plant operator must ensure that the upper/lower limit values shown on the type plate are not overflown or underflown in operation.
  • Page 13: Responsibility Of User

    ● Installation, commissioning, maintenance and inspection may only be carried out by skilled persons having knowledge of the relevant rules and regulations for potentially explosive atmospheres, especially: – Ignition protection types – Installation regulations – Zone classification FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 14: Correct Use

    Only use the FLOWSIC600-XT as described in these Operating Instructions. The manu- facturer bears no responsibility for any other use. ▸ Do not carry out any work or repairs on the FLOWSIC600-XT not described in these Operating Instructions. ▸ Do not remove, add or change any components in or on the FLOWSIC600-XT unless such changes are officially allowed and specified by the manufacturer.
  • Page 15: Product Description

    Measuring principle System components Features and applications Operating software FLOWgate Operating modes, meter states and signal output Interfaces Totalizers Diagnostics function i-diagnostics Data processing in FLOWSIC600-XT Sealing PowerIn Technology FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 16: Measuring Principle

    Measuring principle 2 . 1 The FLOWSIC600-XT measuring system works according to the principle of ultrasonic tran- sit time difference measurement. This allows conclusions to be made on the gas volume flowing through based on the sound velocity transfer time. Measurement is carried out in a direct path layout to keep disturbing effects such as gas flow turbulence, dirt, moisture or interfering noises as low as possible.
  • Page 17: Meter Body

    Ultrasonic transducers 2.2.2 Ultrasonic transducers optimally tuned to system requirements are fitted on the FLOWSIC600-XT. The high quality of the transducer design provides the basis for accurate and highly stable transit time measurement of the ultrasonic signals with nanosecond precision.
  • Page 18: Correction In Flowsic600-Xt Electronics

    If no current process values for pressure and temperature are available to the FLOWSIC600-XT due to a failure of external sources (volume converter or pressure and temperature transmitter), the device makes the correction based on the last known pressure and temperature values.
  • Page 19 4 The actual temperature and pressure difference in the calibrated state must be calculated for the geometry correction in the volume converter according to the equations: – Δ – T in °C) – Δ – p in bar(a)) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 20: Features And Applications

    FLOWSIC600-XT FLOWSIC600-XT 2plex 2.3.2 The FLOWSIC600-XT 2plex is a very compact combination of a gas flow meter for custody transfer with a control measuring device, and provides advanced diagnostics functionality with an additional independent measuring path. With their different path arrangements and the resulting difference in sensitivity, the...
  • Page 21: Flowsic600-Xt Quatro

    Fig. 6 FLOWSIC600-XT Quatro FLOWSIC600-XT Forte 2.3.4 The FLOWSIC600-XT Forte provides eight paths on two different path levels and is especially suitable for installation in systems with short inlet and outlet sections. Fig. 7 FLOWSIC600-XT Forte FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 22: Flowsic600-Xt C

    Product description FLOWSIC600-XT C 2.3.5 The FLOWSIC600-XT C is a 4-path meter for all gas applications subject to custody transfer similar to the FLOWSIC600-XT, but with a different meter body shape. Optional functions such as the integrated pressure/temperature sensor or i-diagnostics are not available.
  • Page 23: Operating Software Flowgate Tm

    For information on FLOWgate operating software, see “Software Manual FLOWgate ”. The Software Manual is on the delivered Product CD or the SICK Product web site. The Software Manual is also available using the Help function of the FLOWgate operating software.
  • Page 24: System Requirements

    Access rights 2.4.3 The FLOWSIC600-XT provides not only various access levels but also allows several single users per access level. Only one user can be logged onto the device at any one time. Three different users with the same access rights are possible for access levels “User” and “Authorized user”.
  • Page 25: Operating Modes, Meter States And Signal Output

    The FLOWSIC600-XT can have the following status during measuring mode: ● Measurement valid ● Measurement invalid ● Maintenance request In measuring mode, the FLOWSIC600-XT operates in one of three meter statuses depend- ing on the measuring conditions. Air test mode 2.5.2 Air test mode serves to carry out a test bench calibration with the test medium air at ambient pressure.
  • Page 26: Interfaces

    Digital outputs 2.6.2 The FLOWSIC600-XT has 4 digital outputs (FO.0, FO.1, DO.2 and DO.3) to output the impulses proportional to the flow rate and status information. The digital outputs are electrically isolated with a synchronous refresh in a configurable period between 0.1 to 1 s.
  • Page 27 FO.0 and FO.1 output a signal with a phase offset of 90°. FO.0 leads for positive values and follows for negative values. Phase offset 90 ° Fig. 11 Forward flow Reverse flow FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 28: Encoder Totalizer

    Compatibility with the downstream device is ensured when this device runs with the same interface protocol. It is recommended to check this during an operating point test. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 29: Serial Data Interfaces

    Instructions FLOWSIC600-XT: Interfaces”. Optical data interface 2.6.5 The FLOWSIC600-XT has an optical interface compliant with IEC 62056-21 on the front panel with bit-serial, asynchronous data transfer (protocol MODBUS RTU). A computer can be connected using an infrared/USB adapter (Part No. 6050602).
  • Page 30: Fingerprint System

    The data records of the different operating states are divided into different “classes” by the flow velocity. Comparisons between reference data and current data are only made in data records of the same class. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 31 -11..-23 m/s -11..-23 m/s filled class -23..-45 m/s -23..-45 m/s Point 8 Not filled class Indicator active? Indicators Turbulence Noise (AGC+SNR) Symmetry Twist Indicator > Limit ? Warning! FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 32: Data Processing In Flowsic600-Xt

    The metrology logbook can be reset only when the parameter locking switch is open. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 33: Archives

    ) The values are throughflow-weighted in the recording direction when the throughflow was within the period in recording direction. The values are averaged when no throughflow existed within the period. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 34: Protection Of Parameters From Undesired Changes

    These changes are possible only when free entries exist in the metrology logbook. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 35: Sealing

    “Increased Safety” and Ex-i “Intrinsically Safe”. If the manufacturer's adhesive label has been broken, sealing can also be carried out using screws with cross or longitudinal holes and wire seals. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 36 Seals on the transducer cover caps The cover caps are sealed with at least one adhesive label that must be glued over the openings of the fastening screws. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 37: Powerin Technology Tm

    Approx. 2 8-path electronics month month months months months Approx. 5 months Approx. 2 Approx. 2 Approx. 2 Approx. 3 Approx. 3 1-path electronics months months months months months FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 38 Product description FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 39: Installation

    Installation FLOWSIC600-XT Installation Hazards during installation General information Mechanical installation Electrical installation FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 40: Hazards During Installation

    Persons carrying out installation work must be familiar with the directives and standards applicable for pipeline construction and have the corresponding qualifications, e.g. in accordance with DIN EN 1591-4. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 41: General Information

    If it is determined that the sensors cannot withstand the pressure, dummy plugs must be installed instead. SICK will make a recommendation for the dummy plugs as well as for the corresponding O-rings to be used for the water pressure test (dummy plugs and O-rings must be ordered separately!).
  • Page 42: Mechanical Installation

    (external and internal corrosion). The FLOWSIC600-XT can be installed in straight inlet and outlet pipes depending on the installation configuration (→ p. 45, §3.3.4.1): The inlet and outlet pipes must have the same nominal size as the meter body. The inner diameter is shown in the Data Sheet and is based on the nominal flange value and the standard.
  • Page 43: Fitting In The Pipeline

    45 ° 45 ° ▸ If a lifting angle of 45° cannot be ensured due to construction of the FLOWSIC600-XT, e.g. for 2plex devices, a suitable traverse hoist must be used for lifting. ▸ For meters of nominal size DN80/3" and DN100/4" with double electronics (Y-neck), the lifting lugs for correct alignment of the electronics must be removed and replaced with dummy plugs.
  • Page 44 “+”. ▸ The measured volume is displayed with a negative sign when the meter is flowed through in reverse direction marked with “-”, . FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 45: Installation Configurations

    Characterized by CPA or SICK flow conditioners. Better repeatability and linearity is achieved by using a flow conditioner; but both configurations meet the performance requirements of AGA 9. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 46 Installation requirements in accordance with GOST, see document “8020847 Installation Requirements GOST” The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 47 5 DN AGA Report 9 3rd Edition, July 2017 4 measuring paths Metering package performance per §6.3 10 DN 8 measuring paths Metering package performance per §6.3 5 DN FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 48 5 DN 2.5 DN §6.3 8 measuring paths Metering package performance per 6 DN 3 DN 3 DN 2.5 DN §6.3 Characterized by CPA or SICK flow conditioners. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 49 Installation requirements in accordance with GOST, see document “8020847 Installation Requirements GOST” The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 50 Mark the pipes and flow conditioner to indicate the flange alignment at the time of calibration. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 51 [2] Class 0.5 is only achieved for the 8-path meter in this configuration. The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 52 5DN inlet length must be considered. When other conditioners are used, the installation configuration can be different and must be agreed with SICK. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 53 [2] Class 0.5 is only achieved for the 8-path meter in this configuration. The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 54: Fitting The Flowsic600-Xt In The Pipeline

    Installation Fitting the FLOWSIC600-XT in the pipeline 3.3.4.2 1 Use the lifting gear to position the FLOWSIC600-XT in the desired location in the pipe- line. 2 Lead the pipelines free of tension to the device being fitted. 3 Check for correct seating and alignment of the flange gaskets after installing the flange bolts, but prior to tightening.
  • Page 55 Mounting set BZ 4" A0150RF CL150 2096371 B7/2H VZ3.1 Mounting set BZ 4" A0600RF CL600 50,4 2096375 B7/2H VZ3.1 Mounting set BZ 4" PN063b! 5.6 PN063 2096376 VZ3.1 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 56: Signal Processing Unit Alignment

    2 Turn the meter body to the desired position. 3 Retighten the three screws on the meter body neck that were previously loosened (5Nm). Fig. 26 Signal Processing Unit alignment FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 57: Electrical Installation

    3 .4 Requirements for use in potentially explosive atmospheres 3.4.1 The FLOWSIC600-XT is as suitable for use in potentially explosive atmospheres classified in Zone 1 and Zone 2. IECEx Ex db ia op is [ia Ga] IIA /IIC T4 Gb...
  • Page 58 (exception: under the conditions already described). ▸ The display cover may be opened during operation, for example, in order to swap the battery. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 59 See → p. 57, §3.4 and → p. 132, §9.1 “Connection diagrams for operation of the FLOWSIC600-XT in accordance with ATEX/IECEx” or → p. 141, §9.2 “Connection diagrams for operation of the FLOWSIC600-XT in accordance with CSA” for correct electric installation.
  • Page 60 The ambient temperature must be within the range specified on the Signal Processing Unit type plate. The meter body becomes part of the pipeline as soon as the FLOWSIC600-XT is installed in the pipeline. The wall of the pipeline and the meter body are then deemed a zone- separating barrier.
  • Page 61 Additional requirements for operation of ultrasonic transducers in Zone 0 classified areas FLOWSIC600-XT is either available in the completely intrinsically safe variant and is identified with device protection level Ga after the temperature class or the identification contains, among others [ia Ga], which identifies the intrinsically safe control of the ultrasonic transducers.
  • Page 62 After de- installation and before every reinstallation the seals must be replaced according to the orig- inal assembly. Seals can be ordered from SICK (part number and serial number from type plate at Signal Processing Unit).
  • Page 63: General Connection Of The Flowsic600-Xt

    Ex i Ex i Ex i Ex i Ex i Safe area Ex zone classified Zone 1 or Zone 2 6...16 V DC FLOWSIC600-XT FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 64: Criteria For Electrical Connection

    Electrical connections 3.4.4 The Signal Processing Unit enclosure of the FLOWSIC600-XT comprises a flameproof enclo- sure and an adjacent separate chamber. With Ex-e wiring (→ Fig. 30), the Ex-d inputs and outputs run through a line duct to the Ex-e terminals in the Ex-e terminal compartment.
  • Page 65 3 Cable gland (5x M20 or 1/2“ NPT) 4 Ex-e terminal compartment 5 Ex-e terminal compartment cover 6 Ex-i transducer electronics with cover and backup battery 7 Display unit FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 66 1 Cable gland (5x M20 or 1/2“ NPT) 2 Ex-i terminal compartment 3 Ex-i terminal compartment cover 4 Ex-i transducer electronics with cover and backup battery 5 Display unit FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 67: Available Input/Output Configurations

    Status Status Pulse Pulse Analog code Output Output Output Output Output Modules Intrinsically safe Version (Ex i) Flameproof enclosure / increased type of protection (Ex d / e) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 68: Cable Specifications

    Ex d/de Cable diameter 6 … 12 mm Fixing range of the cable glands OZ-BL-CY 2x1.5 mm² is only suitable for the power supply of the FLOWSIC600-XT. Digital output, current output, encoder, pressure and temperature sensors Specification Remark Type of cable...
  • Page 69: Checking The Cable Loops

    Reconnect all cables after the loop resistance test. NOTICE: Incorrect cabling may cause failure of the FLOWSIC600-XT! This will invalidate warranty claims. The manufacturer assumes no liability for consequential damage. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 70: Connection Parameters Of Inputs And Outputs

    → Fig. 72, → p. 141 → Fig. 64, → p. 133 → Fig. 73, → p. 142 → Fig. 65, → p. 134 → Fig. 74, → p. 143 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 71: Connection Parameters Ex-D And Ex-E

    – Bit protocol: 8N1 Ethernet Ethernet 9-12 10/100 Mbit/s, protocol Modbus TCP [1] If configured Configuration options and power input of possible configurations, see → p. 158, §9.4. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 72: Ex-D Terminal Compartment

    Ex-d terminal compartment cover with an SW5 Allen key until the tip of the screw slightly enters the material of the cover. Do not operate the device without the securing screw! FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 73 RS485.3 3 DO.3 Status output pT (HART master) 4 DO.2 Status output 10 RS485.2 5 DO.1/FO.1 Pulse output 11 Ethernet (when configured) 6 DO.0/FO.0 Pulse output 12 Power FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 74: Ex-E Terminal Compartment

    2 Position the cover on the Ex-e terminal compartment. 3 Tighten the 3 screws (captive) of the Ex-e terminal compartment cover with an SW4 Allen key (torque 5 Nm). FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 75 Open Collector NAMUR DO.1/FO.1 DO.1/FO.1 Open Collector NAMUR DO.2 DO.2 Open Collector NAMUR DO.3 DO.3 Open Collector NAMUR RS485.1 (MOD), Modbus RTU Not used Not used [1] If configured FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 76: Ex-I Terminal Compartment

    Swivel the display unit downwards, → p. 107, §5.3.3.1. ▸ Connect the backup battery, → p. 108, §5.3.3.3. ▸ Swivel the display unit upwards and lock, → p. 109, §5.3.3.4. Fig. 36 Backup battery connected FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 77: Connecting External Pressure And Temperature Sensors To The Electronics

    It is possible to connect external pressure and temperature transmitters via HART to the electronics of the FLOWSIC600-XT. Select the electronics version with the option “HART p/T modules” in this case. This is available in all three Ex versions (Ex i, Ex d, Ex e) (Table 3 “Available input/output configurations”...
  • Page 78 Installation FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 79: Commissioning And Operation

    Commissioning and Operation FLOWSIC600-XT Commissioning and Operation General information Parameter display on the display Commissioning with the FLOWgate operating software Function check after commissioning Sealing FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 80: General Information

    All measures must be carried out on the basis of this Manual and, when necessary, the Service Manual (Part No. 8019178). In all other cases, the output parameters of the FLOWSIC600-XT can be adapted on site by trained staff. ● The commissioning of FLOWSIC600-XT is supported by the field setup wizard in the FLOWgate™...
  • Page 81: Parameter Display On The Display

    Do not remove the display protective flap. Always keep the display protective flap closed when the display is not in use! After the end of the work, screw the display protective flap tight. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 82: Display And Operating Elements

    Metrologically relevant parameters can be changed; the open modifications are not saved in the Metrology logbook. Configuration mode Configuration mode is active, parameters can be changed on the device. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 83: Configurable Standard Display

    Volume at base conditions, reverse, interrupted 000000123 m³ Volume at base conditions, forward, total 000012468 m³ Volume at base conditions, reverse, total 000012468 m³ [1] Only visible when volume conversion is active FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 84 Mass, forward, interrupted 000000123 tn Mass, reverse, interrupted 000000123 tn Mass, forward, total 000012468 tn Mass, reverse, total 000012468 tn [1] Only visible when volume conversion is active FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 85: Menu Structure

    Checksum for metrological parameters Min. oper. pressure Minimum operating pressure Max. oper. pressure Maximum operating pressure Impulse factor Impulse factor [1] Only visible in configuration with integrated EVC FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 86: Commissioning With The Flowgate Tm Operating Software

    A data connection can be established with the device using the optical data interface and the infrared/USB adapter HIE-04 (Part No. 6050602). This interface serves to configure the FLOWSIC600-XT. The infrared/USB adapter has an USB 2.0 interface. This interface provides the connection to the PC and transfers the FLOWSIC600-XT data.
  • Page 87: Field Setup Wizard

    Check the serial numbers and specific device values against the type plate. Device information ▸ Compare the model name against the type plate and ensure the FLOWSIC600-XT is suitable equipped for the application. Detailed description of the model name, see → p. 161, §9.6.
  • Page 88: System/User

    Up to three users and authorized users can be created. For access rights for single user levels, see → p. 24, Access rights. Fig. 40 Example: New users FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 89: I/O Configuration

    This value is stored in Register #4015 “Impulse_HoldTime” of the meter. The function can be used, for example, to bridge short-term disturbances for control purposes. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 90: P + T Pressure And Temperature Sensor

    The standard limits for natural gas applications are set at the factory. ▸ Activate single warnings as desired: Fig. 42 Example: System warnings SICK recommends adapting the limit values to the application conditions after several weeks of measuring operation. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 91: Meter Installation

    Zero phase check, → p. 92, §4.4.3. ▸ Checking the speed of sound, → p. 93, §4.4.4. ▸ Comparing theoretical and measured sound velocity (SOS), → p. 98, §5.2.2. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 92: Checking The Signal Acceptance Rate

    The “Phase shift” parameter of a path is properly adjusted when the values are lower than 0.2. An adjustment coordinated with SICK Service is recommended when the zero phases do not meet the specified criteria. Fig. 44 Zero phase check FLOWSIC600-XT ·...
  • Page 93: Checking The Speed Of Sound

    ▸ Check the speed of sound (SOS). ▸ The speed of sound values must be almost identical on all paths of the FLOWSIC600-XT and may only differ by less than 0.1%. ▸ When moving the mouse over the bar graphs, the current measured values are shown in the diagram.
  • Page 94: Path Failure Compensation

    Path failure compensation 4.4.5 The FLOWSIC600-XT can compensate failed measuring paths. A path is considered failed when its acceptance rate is below a certain limit. It is then no longer used to create measured values, but is substituted by a configured or teached relation to the overall veloc- ity.
  • Page 95: Maintenance

    Maintenance FLOWSIC600-XT Maintenance General information Routine checks Exchanging the battery Cleaning the FLOWSIC600-XT FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 96: General Information

    Routine checks 5 . 2 Proper device function can be determined directly on the front panel of the FLOWSIC600-XT. The FLOWgate™ operating software provides a user-friendly option for the performance of routine checks (connect to the device, → p. 86, §4.3.1).
  • Page 97: Function Check With Flowgate Tm

    The current Status overview opens and shows details and information on how to proceed. Fig. 46 Current status The “Diagnostics” menu shows under “Meter values” in various profiles all diagnostics values providing information on the status of the device. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 98: Comparing Theoretical And Measured Sound Velocity (Sos)

    3 Select the gas composition and confirm with “Apply”. The gas composition can be entered manually or loaded as file. 4 Enter the current process conditions and select “Calculate SOS”. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 99 6 The deviation between the two speeds of sound should be less than ±0.1%. If the deviation exceeds 0.3%: Check the plausibility of the pressure, temperature and gas composition values. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 100: Time Synchronization

    Time synchronization via Modbus 5.2.3.1 The FLOWSIC600-XT has a real-time clock which continues to run also in the case of a power failure. The real-time clock has a separate battery (BR2032). The time is saved as UNIX Timestamp (UTC) in the device and in the stored data records. The UNIX Timestamp specifies the number of seconds since 01.01.1970 with leap year correction.
  • Page 101: Maintenance Report

    PDF document or sent via e-mail. 4 Finally close the report with the “Close” button. 5 It is recommended to file the printed report with the device delivery documentation. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 102: Optional Data Backup

    Example: Event logbook Deleting logbook entries Logbook entries can be deleted only via the FLOWgate™ operating software with button “Clear all Logbooks”. Deleting the entries in FLOWSIC600-XT is not possible. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 103: Checking The Data Archives (Data Logs)

    The report can be created at any time and stored as a PDF document. This enables, for example, trend reporting over the lifetime of the meter with which process or meter changes can be detected. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 104 Select “Load Fingerprint Archive from Device” to load the current process data from FLOWSIC600-XT into the FLOWgate database. This process may take a few seconds depending on the amount of data. The data is displayed in tabular form in the “Finger- print Archive”.
  • Page 105: Exchanging The Battery

    ● Only PANASONIC batteries type BR2032 are permitted as the RTC battery otherwise the intrinsic safety is endangered. ● Only replace the backup battery with a similar type from SICK with item number 2079721 otherwise the intrinsic safety is endangered.
  • Page 106 ▸ If anything is unclear, contact the local office of the Environmental Protection Agency (EPA). In other countries: Please observe national regulations for the disposal of lithium batteries. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 107: Replacing The Backup Battery

    2 Swivel down the display protective flap. 3 Loosen the 4 screws on the display unit with an SW4 Allen key. 4 Carefully swivel the display unit downwards. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 108: Remove The Backup Battery

    Otherwise the backup battery is immediately active. 4 Insert the backup battery in the holder and connect to the “Backup Battery” connection. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 109: Swivel The Display Unit Upwards And Lock

    This must be coordinated with the authorities before carrying out the measures. ▸ All actions must be performed on the basis of this Manual and, if necessary, the Service Manual for the product. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 110 9 Connect with the device using the FLOWgate operating software, → p. 86, §4.3.1. 10 Open the System/User tile in the Parameter Modification menu. 11 Set the date and time or synchronize with the PC. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 111: Cleaning The Flowsic600-Xt

    0 location. (See clause 7.4.2 of EN 60079-0) (See § 7.4.2 EN 60079-0) ▸ Only use cleaning agents free from oil, grease and solvents to clean the display. ▸ Use a damp cloth for cleaning. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 112 Maintenance FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 113: Shutting Down

    Shutting down FLOWSIC600-XT Shutting down Returning Disposal information FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 114: Returning

    6 . 2 Materials 6.2.1 The FLOWSIC600-XT mainly consists of steel, aluminium and plastic materials. It does not contain any poisonous, radioactive or environmentally hazardous substances. Substances from the pipeline could possibly penetrate the seals or deposit on these. Disposal 6.2.2...
  • Page 115: Troubleshooting

    Troubleshooting FLOWSIC600-XT Troubleshooting Status messages Starting a diagnostic session FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 116: Status Messages

    Parameter invalid 3005 Archive checksum error 3006 Time invalid 3007 System test active 3008 Run-time measurement mode 3009 DSP hardware failed 3010 DSP parameter invalid 3011 Error path failure FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 117: Starting A Diagnostic Session

    The diagnostic sessions are saved as files with the ending .sfgsession. The files are saved by default under: C:\Users\Public\Documents\SICK\FLOWgate The name of the storage folder consists of device type and serial number of the device. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 118 Troubleshooting FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 119: Specifications

    Specifications FLOWSIC600-XT Specifications Conformities Technical data Measuring ranges Dimensions FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 120: Conformities

    Specifications Conformities 8 . 1 CE certificate 8.1.1 The FLOWSIC600-XT has been developed, manufactured and tested in accordance with the following EU Directives: ● Pressure Equipment Directive 2014/68/EU ● ATEX Directive 2014/34/EU ● EMC Directive 2014/30/EU ● Measuring Instrument Directive 2014/32/EU Conformity with the above directives has been verified and the device has been marked with the CE label.
  • Page 121: Technical Data

    –40 °C ... +70 °C (–60 °C ... +70 °C for the meter body) Ambient humidity ≤ 95 % relative humidity, non-condensing Ambient pressure 0.8 ... 1.1 bar Contamination level FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 122 Modbus RTU Modbus TCP (optional) Register assignments (optional): DSFG, instance F / ISO 17089 FLOWSIC600-compatible Modbus registers Operation Via meter display (read access) and the FLOWgate operating software FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 123 Data archives 1 diagnostics archive (6,000 entries) 2 configurable measuring period archives (6,000 entries each) Logbooks Event logbook (1,000 entries) Parameter logbook (200 entries) Metrology logbook (50 entries) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 124: Measuring Ranges

    100.000 120.000 Only the “Standard flow range according to MID" is applicable for device version FLOWSIC600-XT C. The maximum gas velocity in the pipe is limited to 40 m/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 125 3.532.000 4.238.000 Only the “Standard flow range according to MID" is applicable for device version FLOWSIC600-XT C. The maximum gas velocity in the pipe is limited to 131 ft/s in configurations with flow conditioner. FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 126: Dimensions

    8 . 4 Fig. 59 FLOWSIC600-XT and FLOWSIC600-XT Forte Fig. 60 FLOWSIC600-XT 2plex and FLOWSIC600-XT Quatro " version for pressure levels up to Class 600/PN100 Fig. 61 FLOWSIC600-XT: 3 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 127 PN 100 EN 1092-1 8" cl. 150 ANSI B16.5 cl. 300 cl. 600 cl. 900 DN200 PN 16 EN 1092-1 PN 63 EN 1092-1 PN 100 EN 1092-1 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 128 Data on request DN550 24" cl. 150 ANSI B16.5 1090 cl. 300 1390 cl. 600 1615 cl. 900 2100 1200 1040 1040 DN600 PN 16 EN 1092-1 1015 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 129 600 5450 1444 1404 cl. 900 Data on request 1523 1562 DN1050 PN 16 Data on request 44" Data on request DN1100 46" Data on request DN1150 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 130 [1] Devices with one Signal Processing Unit; devices with two Signal Processing Units: weight + 7 kg [2] Optional neck extension: B + 200 mm [3] For versions with flange in 5DN overall length FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 131: Annex

    ATEX/IECEx Connection diagrams for operation of the FLOWSIC600-XT in accordance with CSA Wiring examples Power input of the possible input and output configurations Type plates (examples) Model name FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 132: Connection Diagrams For Operation Of The Flowsic600-Xt In Accordance With

    Annex Connection diagrams for operation of the FLOWSIC600-XT in 9 . 1 accordance with ATEX/IECEx Fig. 63 Connection diagram 9236580 (page 1) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 133 Annex Connection diagram 9236580 (page 5) Fig. 64 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 134 Annex Connection diagram 9236580 (page 6) Fig. 65 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 135 Annex Connection diagram 9236580 (page 7) Fig. 66 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 136 Annex Connection diagram 9236580 (page 8) Fig. 67 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 137 Annex Connection diagram 9236580 (page 12) Fig. 68 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 138 Annex Connection diagram 9236580 (page 13) Fig. 69 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 139 Annex Connection diagram 9236580 (page 14) Fig. 70 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 140 Annex Connection diagram 9236580 (page 15) Fig. 71 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 141: Csa

    Annex Connection diagrams for operation of the FLOWSIC600-XT in 9 .2 accordance with CSA Fig. 72 Connection diagram 9236581 (page 1) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 142 Annex Connection diagram 9236581 (page 5) Fig. 73 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 143 Annex Connection diagram 9236581 (page 6) Fig. 74 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 144 Annex Connection diagram 9236581 (page 7) Fig. 75 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 145 Annex Connection diagram 9236581 (page 8) Fig. 76 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 146 Annex Connection diagram 9236581 (page 12) Fig. 77 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 147 Annex Connection diagram 9236581 (page 13) Fig. 78 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 148 Annex Connection diagram 9236581 (page 14) Fig. 79 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 149 Annex Connection diagram 9236581 (page 15) Fig. 80 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 150: Wiring Examples

    Annex Wiring examples 9 . 3 Ex-d (flameproof enclosure) 9.3.1 Fig. 81 Wiring example Ex-d (3 x RS485) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 151 Annex Fig. 82 Wiring example Ex-d (2 x RS485, 1 x Encoder) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 152 Annex Fig. 83 Wiring example Ex-d (2 x RS485, 1 x Ethernet) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 153: Ex-E (Increased Type Of Protection)

    Annex Ex-e (increased type of protection) 9.3.2 Fig. 84 Wiring example Ex-e (3 x RS485) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 154 Annex Fig. 85 Wiring example Ex-e (2 x RS485, 1 x Encoder) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 155 Annex Fig. 86 Wiring example Ex-e (2 x RS485, 1 x Ethernet) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 156: Ex-I (Intrinsically Safe)

    Annex Ex-i (intrinsically safe) 9.3.3 Fig. 87 Wiring example Ex-i (3 x RS485) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 157 Annex Fig. 88 Wiring example Ex-i (2 x RS485, 1 x Encoder) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 158: Power Input Of The Possible Input And Output Configurations

    Annex Power input of the possible input and output configurations 9 . 4 Fig. 89 Power input FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 159: Type Plates (Examples)

    Pressure Equipment Directive type plate (example) FLOWSIC600-XT Serial No. 12345678 05/2016 Year DN/NPS 300/12” Weight 720 kg Fluid Gr. -45/+80°C 120 bar 230 bar Made in Germany 4089591 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 160 Annex Fig. 93 FLOWSIC600-XT Gateway type plate (example) FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 161: Model Name

    Annex Model name 9 .6 FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 162: Spare Parts

    Annex Spare parts 9 . 7 SICK recommends the following spare parts with the purchase of the gas flow meter. For a configuration with a different electronics-transducer combination, please ask your SICK sales partner for the corresponding spare parts. Designation Part No.
  • Page 163 Annex FLOWSIC600-XT · Operating Instructions · 8018846/1BHP/V 2-1/2021-05 · © SICK Engineering GmbH...
  • Page 164 Netherlands Taiwan China New Zealand Thailand Denmark E-Mail sick@sick.dk E-Mail sales@sick.co.nz Turkey Finland Norway E-Mail sick@sick.no United Arab Emirates France Poland United Kingdom Germany Romania Greece Russia Vietnam Hong Kong Singapore www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

Table of Contents

Save PDF