Title Page MMMOPERATING INSTRUCTIONS MMMI O P E R A T I N G I N S T R U C T I O N S FLOWSIC600 DRU/DRU-S Gas Flow Meters Gas flow meters for applications in natural gas production...
Page 2
Original document This document is an original document of SICK Engineering GmbH. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/V1-0/2021-06 | SICK Subject to change without notice...
DataLogs / Archives ..............26 3.7.4 Diagnostics Comparison Log ............27 8026711/V1-0/2021-06 | SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 4
Activating path compensation ..............61 Documentation ..................... 61 O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/V1-0/2021-06 | SICK Subject to change without notice...
Page 5
Intrinsically safe installation ............99 8.10.2 Non-intrinsically safe installation..........100 8026711/V1-0/2021-06 | SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Mass flow rate s.c. lbs/h lbs/h Table 1: Abbreviations for measured variables 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Important technical information for this product Important information on electrical or electronic functions O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
The pressure during flushing must not be higher than 1.2 times the nominal pressure (with built-in sensors). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
The result of improper use can be the failure of the ultrasonic sensors and consequently the failure of the entire gas flow meter. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
5 Sensor cover 3 SPU Fig. 1: FLOWSIC600 DRU components O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
The application range of the FLOWSIC600 DRU for different diameters is shown in the following diagram. Fig. 2: Application range DRU 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
“Full-bore” design ● Diagnostic feature wet gas detection (option) ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
UL Std. No. 1203 with the “Explosion-Proof Enclosure” type of ignition protection. The ultrasonic sensors are electrically intrinsically safe and non-sparking. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
#3502 “AvgBlockSize”. If no result can be calculated due to poor O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Page 17
“Measurement valid” or “Maintenance request”. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
The default setting for “Maintenance request”, “Configuration” and “Measurement invalid” is “normally closed”. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 19
● “W” for Warning ● “E” for Error ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Fig. 5: Menu “System/Profile” Fig. 6: Menu “Path Warnings” O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
6 Switch wet gas detection on/off via register #3840. Fig. 9: Menu “Wet gas indicator on/off” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Warning logbook [2] to “rolling” to avoid rapid filling of logbook in this case. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Mass total (reverse) Error mass (forward) Error mass (reverse) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
. It is possible to acknowledge individual entries or all entries at once. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 25
“Ackn. All” (Acknowledge all). Fig. 10: Menu “Logbook Management” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
● Standard Volume Counters ● Mass Flow Counters ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Fig. 11: Diagnostics Comparison Log 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
1368 x 768 pixels Microsoft .NET framework 4.6 ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Regional device adaptation User management Table 5: Overview of access rights 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
3 Type plate on the meter body Fig. 13: Markings on FLOWSIC600 DRU/DRU-S O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Unprotected carbon steel surfaces can corrode as a result. Fig. 14: Lifting requirements 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Arrange temperature measuring devices in accordance with the specified installation ● configuration → page 33, 4.2.2. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Fig. 15: Installation scheme FLOWSIC600 DRU, (diameters 3"/ 4" top and 6" bottom) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 34
½" NPT inner Fig. 17: Installation scheme FLOWSIC600 DRU-S, bidirectional O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Check for correct seating and alignment of the flange gaskets after installing the first flange bolts, but prior to tightening. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
- tighten - position Fig. 18: Positioning the SPU O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Class I, Division 2 FLOWSIC600 DRU/DRU-S Fig. 19: FLOWSIC600 DRU/DRU-S connection diagram 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
6 ... 12 mm (1/4 to 1/2 inch) Fixing range of cable glands O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
▸ Reconnect all cables after the loop resistance test. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Fig. 21: Terminal compartment at the rear of the SPU (see Section → 4.4.2 for North American wiring specification equivalents) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 41
● Detailed information, see the Service Manual FLOWSIC600 DRU. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Table 6: Terminals in the signal processing unit terminal compartment O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Fig. 23: FLOWSIC600 DRU/DRU-S components and their type of protection 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 44
-20 °C to 60 °C (-4 °F to 140 °F). Fig. 24: Ex-Zones O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 45
The electronics housing must nevertheless be separately grounded. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 46
O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Page 47
For further details, see drawing no. 781.00.02 (→ page 93, 8.9). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 48
Epoxy and Acrylic RAL9002. This combination ideally protects the meter body from corrosion. The layer thickness is less than 0.2 mm. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Page 49
Table 7: Safety-relevant data of inputs and outputs only for FLOWSIC600 DRU/DRU-S according to Class-Division and Class-Zone certification 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Commissioning the FLOWSIC600 DRU/DRU-S is supported by the Field Setup wizard in ● the FLOWgate O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
5 Check the “Serial Port” box. Fig. 26: Menu “Interface Selection” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 52
10 Login with user “Authorized operator“. → page 29, 3.8.4 O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
“ProgramCRC”) and can be verified as mentioned above. Device identification Fig. 29: FLOWgate overview 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Compare the data with the delivery documentation and adapt as necessary. Fig. 31: Field Setup wizard menu “I/O Setup” O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
SICK recommends creating a Parameter report and Status report and archiving the reports with the delivery documentation. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
The logbook contains detailed error information. For troubleshooting, see → page 66, O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 58
0.3% from a theoretical SOS calculated from gas composition, pressure and temperature, → page 63, O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 59
Perform check of zero phases for each individual path of the FLOWSIC600 DRU/DRU-S. Fig. 36: Selection of path to be checked 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 60
0.3%: Check the plausibility of the pressure, temperature and gas composition values. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
File the completed Commissioning protocol together with the delivery documentation. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Maintenance Reports should be comparable or documented separately and taken into account when the data is analyzed. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
▸ Finally close the report with the “Close” button. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
● Outputting a report of the respective archive. ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
It is recommended to use FLOWgate to obtain further information on the meter's health. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
The name of the storage folder consists of device type and serial number of the device. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
“DeviceBusaddress”). The service port always has Bus address “1”. Fig. 47: Dialog window “Configure Serial Connection” for specifying advanced search options O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
The test results have been archived in a traceable manner and can be made available on request. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Device Data Sheet*) * The Device Data Sheet is included in the delivery documentation. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Enclosure rating IP66/IP67 Table 11: Technical data FLOWSIC600 DRU 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 72
≤ 1 W Table 11: Technical data FLOWSIC600 DRU O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
≤ 1 W Table 12: Technical data FLOWSIC600 DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
(15.60) Fig. 49: Dimensional drawing FLOWSIC600 DRU 3 and 4 inch O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Dimensions in mm (inch) (9.84) Fig. 51: Dimensional drawing FLOWSIC600 DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Table 13: Button explanation Parameters can only be changed in “Configuration mode”. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 77
Display total volume counter at flowing conditions forward (+Vo) 141145m3 and reverse (-Vo). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 78
Cancel cancel the dialog. Event is logged in Logbook 1. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 79
- Flow+Malf NO - Flow+Malf NC?? - Flow+F/R NO?? 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 80
- English English - German - French - Russian O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 81
Unauthorized modification of these parameters may lead to failure of the device! 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 82
Acknowledge all entries in the chosen Log- Logbook 1 book. Acknowledge all O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 83
STEP or DATA. 0000 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
The values can be assigned to the desired page and line of the standard display. The two display pages alternate every 5 seconds. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
Return to standard display 34569870 m3 3 x CE/C 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
(This message only appears for about one Press ENTER once second.) Cancel O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
“-” Event timepoint marking the end of a state ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
TransitTimeMode Table 14: Overview of event entries in Meter logbooks O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 89
Table 14: Overview of event entries in Meter logbooks 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 90
CRC invalid Table 14: Overview of event entries in Meter logbooks O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 91
Table 14: Overview of event entries in Meter logbooks 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
CSA SPU assignment → Fig. 58 and following pages. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
North American Directives (NEC, CEC) Fig. 55: Control diagram 781.00.02 (page 1) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 94
ANNEX Fig. 56: Control diagram 781.00.02 (page 2) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 95
ANNEX Fig. 57: Control diagram 781.00.02 (page 3) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 96
ANNEX Fig. 58: Control diagram 781.00.02 (page 4) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 97
ANNEX Fig. 59: Control diagram 781.00.02 (page 5) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 98
ANNEX Fig. 60: Control diagram 781.00.02 (page 6) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Fig. 61: Intrinsically safe installation of the FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Non-intrinsically safe installation Fig. 62: Non-intrinsically safe installation of the FLOWSIC600 DRU/DRU-S O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
Page 101
ANNEX 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
Page 102
E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...