MMMOPERATING INSTRUCTIONS
MMMI
O P E R A T I N G I N S T R U C T I O N S
FLOWSIC600 DRU/DRU-S
Gas Flow Meters
Gas flow meters for applications in natural gas production

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLOWSIC600 DRU and is the answer not in the manual?

Questions and answers

Summary of Contents for SICK FLOWSIC600 DRU

  • Page 1 Title Page MMMOPERATING INSTRUCTIONS MMMI O P E R A T I N G I N S T R U C T I O N S FLOWSIC600 DRU/DRU-S Gas Flow Meters Gas flow meters for applications in natural gas production...
  • Page 2 Original document This document is an original document of SICK Engineering GmbH. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/V1-0/2021-06 | SICK Subject to change without notice...
  • Page 3: Table Of Contents

    DataLogs / Archives ..............26 3.7.4 Diagnostics Comparison Log ............27 8026711/V1-0/2021-06 | SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 4 Activating path compensation ..............61 Documentation ..................... 61 O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/V1-0/2021-06 | SICK Subject to change without notice...
  • Page 5 Intrinsically safe installation ............99 8.10.2 Non-intrinsically safe installation..........100 8026711/V1-0/2021-06 | SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 6: About This Document

    O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 7: Further Information

    Mass flow rate s.c. lbs/h lbs/h Table 1: Abbreviations for measured variables 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 8: Symbols And Document Conventions

    Important technical information for this product Important information on electrical or electronic functions O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 9: For Your Safety

    The pressure during flushing must not be higher than 1.2 times the nominal pressure (with built-in sensors). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 10: General Safety Instructions And Protective Measures

    The result of improper use can be the failure of the ultrasonic sensors and consequently the failure of the entire gas flow meter. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 11: Authorized Personnel

    8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 12: Product Description

    5 Sensor cover 3 SPU Fig. 1: FLOWSIC600 DRU components O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 13: Technical Features Of The Flowsic600 Dru

    The application range of the FLOWSIC600 DRU for different diameters is shown in the following diagram. Fig. 2: Application range DRU 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 14: Flowsic600 Dru-S Overview

    “Full-bore” design ● Diagnostic feature wet gas detection (option) ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 15: Flowsic600 Dru/Dru-S System Components

    UL Std. No. 1203 with the “Explosion-Proof Enclosure” type of ignition protection. The ultrasonic sensors are electrically intrinsically safe and non-sparking. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 16: Operating Modes, Meter States And Signal Output

    #3502 “AvgBlockSize”. If no result can be calculated due to poor O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 17 “Measurement valid” or “Maintenance request”. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 18: Impulse Output And Status Signaling

    The default setting for “Maintenance request”, “Configuration” and “Measurement invalid” is “normally closed”. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 19 ● “W” for Warning ● “E” for Error ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 20: Self-Diagnosis With User Warnings

    Fig. 5: Menu “System/Profile” Fig. 6: Menu “Path Warnings” O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 21: Wet Gas Detection

    6 Switch wet gas detection on/off via register #3840. Fig. 9: Menu “Wet gas indicator on/off” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 22: Signalization Of Wet Gas Detection

    Warning logbook [2] to “rolling” to avoid rapid filling of logbook in this case. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 23: Data Processing In Flowsic600 Dru/Dru-S

    Mass total (reverse) Error mass (forward) Error mass (reverse) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 24: Logbooks

    . It is possible to acknowledge individual entries or all entries at once. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 25 “Ackn. All” (Acknowledge all). Fig. 10: Menu “Logbook Management” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 26: Datalogs / Archives

    ● Standard Volume Counters ● Mass Flow Counters ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 27: Diagnostics Comparison Log

    Fig. 11: Diagnostics Comparison Log 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 28: Flowgate Tm

    1368 x 768 pixels Microsoft .NET framework 4.6 ● O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 29: Installation

    Regional device adaptation User management Table 5: Overview of access rights 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 30: Installation

    3 Type plate on the meter body Fig. 13: Markings on FLOWSIC600 DRU/DRU-S O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 31: Transport And Storage

    Unprotected carbon steel surfaces can corrode as a result. Fig. 14: Lifting requirements 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 32: Installation

    Arrange temperature measuring devices in accordance with the specified installation ● configuration → page 33, 4.2.2. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 33: Installation Configurations

    Fig. 15: Installation scheme FLOWSIC600 DRU, (diameters 3"/ 4" top and 6" bottom) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 34 ½" NPT inner Fig. 17: Installation scheme FLOWSIC600 DRU-S, bidirectional O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 35: Mechanical Installation

    Check for correct seating and alignment of the flange gaskets after installing the first flange bolts, but prior to tightening. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 36: Spu Alignment

    - tighten - position Fig. 18: Positioning the SPU O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 37: Electrical Installation

    Class I, Division 2 FLOWSIC600 DRU/DRU-S Fig. 19: FLOWSIC600 DRU/DRU-S connection diagram 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 38: Cable Specifications

    6 ... 12 mm (1/4 to 1/2 inch) Fixing range of cable glands O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 39: Checking The Cable Loops

    ▸ Reconnect all cables after the loop resistance test. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 40: Terminal Compartment On The Spu

    Fig. 21: Terminal compartment at the rear of the SPU (see Section → 4.4.2 for North American wiring specification equivalents) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 41 ● Detailed information, see the Service Manual FLOWSIC600 DRU. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 42: Operation In Non-Ex Areas

    Table 6: Terminals in the signal processing unit terminal compartment O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 43: Operation In Ex Zones

    Fig. 23: FLOWSIC600 DRU/DRU-S components and their type of protection 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 44 -20 °C to 60 °C (-4 °F to 140 °F). Fig. 24: Ex-Zones O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 45 The electronics housing must nevertheless be separately grounded. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 46 O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 47 For further details, see drawing no. 781.00.02 (→ page 93, 8.9). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 48 Epoxy and Acrylic RAL9002. This combination ideally protects the meter body from corrosion. The layer thickness is less than 0.2 mm. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 49 Table 7: Safety-relevant data of inputs and outputs only for FLOWSIC600 DRU/DRU-S according to Class-Division and Class-Zone certification 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 50: Commissioning

    Commissioning the FLOWSIC600 DRU/DRU-S is supported by the Field Setup wizard in ● the FLOWgate O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 51: Connecting To The Device

    5 Check the “Serial Port” box. Fig. 26: Menu “Interface Selection” 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 52 10 Login with user “Authorized operator“. → page 29, 3.8.4 O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 53: Identification

    “ProgramCRC”) and can be verified as mentioned above. Device identification Fig. 29: FLOWgate overview 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 54: Field Setup Wizard

    Compare the data with the delivery documentation and adapt as necessary. Fig. 31: Field Setup wizard menu “I/O Setup” O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 55: I/O Configuration

    SICK recommends creating a Parameter report and Status report and archiving the reports with the delivery documentation. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 56: Functional Test On The Device

    The logbook contains detailed error information. For troubleshooting, see → page 66, O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 57: Function Check With Flowgate

    8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 58 0.3% from a theoretical SOS calculated from gas composition, pressure and temperature, → page 63, O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 59 Perform check of zero phases for each individual path of the FLOWSIC600 DRU/DRU-S. Fig. 36: Selection of path to be checked 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 60 0.3%: Check the plausibility of the pressure, temperature and gas composition values. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 61: Activating Path Compensation

    File the completed Commissioning protocol together with the delivery documentation. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 62: Maintenance

    Maintenance Reports should be comparable or documented separately and taken into account when the data is analyzed. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 63: Routine Checks With Flowgate Tm

    8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 64: Time Synchronization

    ▸ Finally close the report with the “Close” button. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 65: Optional Data Backup

    ● Outputting a report of the respective archive. ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 66: Troubleshooting

    It is recommended to use FLOWgate to obtain further information on the meter's health. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 67: Creating A Diagnostic Session With Flowgate Tm

    The name of the storage folder consists of device type and serial number of the device. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 68: Troubleshooting When Connecting Meters

    “DeviceBusaddress”). The service port always has Bus address “1”. Fig. 47: Dialog window “Configure Serial Connection” for specifying advanced search options O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 69: Annex

    The test results have been archived in a traceable manner and can be made available on request. 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 70: Type Code

    Device Data Sheet*) * The Device Data Sheet is included in the delivery documentation. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 71: Technical Data Flowsic600 Dru

    Enclosure rating IP66/IP67 Table 11: Technical data FLOWSIC600 DRU 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 72 ≤ 1 W Table 11: Technical data FLOWSIC600 DRU O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 73: Technical Data Flowsic600 Dru-S

    ≤ 1 W Table 12: Technical data FLOWSIC600 DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 74: Dimensional Drawings

    (15.60) Fig. 49: Dimensional drawing FLOWSIC600 DRU 3 and 4 inch O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 75: Dimensional Drawing Flowsic600 Dru 6 Inch

    Dimensions in mm (inch) (9.84) Fig. 51: Dimensional drawing FLOWSIC600 DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 76: Operation And Menu Structure Of The Meter Body With Lcd Display

    Table 13: Button explanation Parameters can only be changed in “Configuration mode”. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 77 Display total volume counter at flowing conditions forward (+Vo) 141145m3 and reverse (-Vo). 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 78 Cancel cancel the dialog. Event is logged in Logbook 1. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 79 - Flow+Malf NO - Flow+Malf NC?? - Flow+F/R NO?? 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 80 - English English - German - French - Russian O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 81 Unauthorized modification of these parameters may lead to failure of the device! 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 82 Acknowledge all entries in the chosen Log- Logbook 1 book. Acknowledge all O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 83 STEP or DATA. 0000 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 84: Displaying Measured Values

    The values can be assigned to the desired page and line of the standard display. The two display pages alternate every 5 seconds. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK...
  • Page 85: Data Editing In Configuration Mode

    Return to standard display 34569870 m3 3 x CE/C 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 86: Resetting The Error Volume Counters

    (This message only appears for about one Press ENTER once second.) Cancel O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 87: Logbooks

    “-” Event timepoint marking the end of a state ● 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 88: Overview Of Event Entries In Meter Logbooks

    TransitTimeMode Table 14: Overview of event entries in Meter logbooks O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 89 Table 14: Overview of event entries in Meter logbooks 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 90 CRC invalid Table 14: Overview of event entries in Meter logbooks O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 91 Table 14: Overview of event entries in Meter logbooks 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 92: Spu Terminal Assignment

    CSA SPU assignment → Fig. 58 and following pages. O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 93: Connection Diagram For Operation Of The Flowsic600 Dru/Dru-S In Ex-Zones Acc. To North American Directives (Nec, Cec)

    North American Directives (NEC, CEC) Fig. 55: Control diagram 781.00.02 (page 1) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 94 ANNEX Fig. 56: Control diagram 781.00.02 (page 2) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 95 ANNEX Fig. 57: Control diagram 781.00.02 (page 3) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 96 ANNEX Fig. 58: Control diagram 781.00.02 (page 4) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 97 ANNEX Fig. 59: Control diagram 781.00.02 (page 5) 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 98 ANNEX Fig. 60: Control diagram 781.00.02 (page 6) O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 99: Wiring Example

    Fig. 61: Intrinsically safe installation of the FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 100: Non-Intrinsically Safe Installation

    Non-intrinsically safe installation Fig. 62: Non-intrinsically safe installation of the FLOWSIC600 DRU/DRU-S O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S 8026711/2021-06| SICK Subject to change without notice...
  • Page 101 ANNEX 8026711/2021-06| SICK O P E R A T I N G I N S T R U C T I O N S | FLOWSIC600 DRU/DRU-S Subject to change without notice...
  • Page 102 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...