The bargraph characteristics can be set to display as either PPM or VU.
On the bargraph display the bar at the '0' position can be set to brighten, when the signal is
either 0dBu, +4dBu, +6dBu or +8dBu.
The headphone output is set to follow the monitor LS outputs. However it can be selected
to be taken either pre or post the LB, RB, Mono & Phase Reverse switching.
Headphone O/P - Pre
Headphone O/P - Post
The headphone output can be as normal, (no phase reverse) or can have a phase reverse
on the Right Signal.
Phase Reverse on Right SW 26
PPM
SW 5
VU
SW 5
0dBu
SW 6
+4dBu
SW 6
+6dBu
SW 6
+8dBu
SW 6
SW 4
SW 4
NML
SW 26
1 -
OFF
Standard default settings
2 -
ON
1 -
ON
2 -
OFF
1 -
ON
2 -
ON
1 -
ON
2 -
OFF
1 -
OFF
2 -
ON
1 -
OFF
Standard default settings
2 -
OFF
1 -
OFF
Standard default settings
2 -
ON
3 -
OFF
4 -
ON
1 -
ON
2 -
OFF
3 -
ON
4 -
OFF
1 -
ON
Standard default settings
2 -
OFF
1 -
OFF
2 -
ON