SPDM CONTROL PANEL
1 TECHNICAL DATA
1.1
Identification
SPDMBX
1,2,3,4,5,6
Product Series
Control board
S = "System2" control board
U = 2 quadrants operation
Operating mode
R = 4 quadrants operation
F = 2 or 4 quadrants with fiber-optic
G = 380-500 V
H = 600 V
K = 690 V
Power supply
voltage
W= 750 V
M = 850
N = 950
B = box (290w x 530h x 178d)
Version
P = panel (555w x 310h x 78d)
N = Not installed
Keypad
H = Installed
N = Not installed
E = EtherNet/IP (GSB40A-EtherNet/IP board)
Communication
Expansions
I = PROFINET IO (GSB40A-PROFINET board)
Note: PROFIBUS DP and Modbus TCP are already included in control board
SYSTEM2
N = Not installed
A = Analog expansion board (GEOSA)
Expansion Boards
T = Analog expansion board for tachogenerator (GTACA)
E = Encoder expansion board (SYSENC)
N = Not installed
Safe Torque Off
function
T = STO board installed
62 = Acid/marine environmental: special tin-plated bars (12μm) and boards with double
Suffix
coating
(Special versions)
80 = I/O Expansion (Relè card)
(*) Fiber optic connection kit and electrical cable kit are not included.
NIDEC ASI S.P.A. – SPDM CONTROL PANEL USER MANUAL
IMSPDCB2EN
S
x
x
7
8
9
B
x
x
10
11
12
1 – TECHNICAL DATA
x
x
..
13
14
15.16
11
Need help?
Do you have a question about the SPDM CONTROL BOX and is the answer not in the manual?
Questions and answers