MKS 901P Short Form Manual

MKS 901P Short Form Manual

Loadlock vacuum transducer
Hide thumbs Also See for 901P:

Advertisement

P/N: 100017411
Short form manual
REV: A, December 2009
Product: 901P-x1090-0072
Connector: 6 pin Hirschmann
Output: 19 (TPR280,TPR265)
RoHS Compliant
Measuring range (N
MP Accuracy
(1)
PZd Accuracy
MP Repeatability
Supply Voltage:
Power consumption:
Fuse (thermal recoverable):
Analog output 1: (100 Ω impedance):
Analog output 1 resolution:
Materials exposed to vacuum:
Internal volume:
Flange and Housing material:
Weight (901P with KF16):
Climate category:
Operating temperature:
Bakeout temperature (Power off):
(1) Refer to Operation and Installation manual for Piezo accuracy details.
(2) Accuracy and repeatability values are typical values measured in Nitrogen atmosphere at
ambient temperature after zero adjustment.
and Air):
2
-4
5×10
to 1×10
-3
1×10
to 100 Torr:
100 to Atm.:
-760 to +100 Torr:
(2)
-3
1×10
to 100 Torr:
KF16 flange
KF16 long flange
KF25 flange
1/8" NPT , VCR8
VCR4 flange
MKS Instruments HPS Products
www.mksinst.com
-5
1×10
-3
Torr:
± 10%
± 5%
± 25%
± 1-10 % of reading
± 2%
9 – 30 VDC
< 1.2 Watt
200 mA
2.199 – 8.625 VDC
16 bit
304 Stainless steel, Silicon
SiO
, Si
2
Low outgassing Epoxy resin
2.8 cm
6.7 cm
3.6 cm
3.1 cm
1.9 cm
Stainless steel 304
170 g
IP40
0 to 40
o
85
C
to 1500 Torr
of reading
of reading
of reading
of reading
N
, gold, Viton
3
4
3
3
3
3
3
o
C
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 901P and is the answer not in the manual?

Questions and answers

Summary of Contents for MKS 901P

  • Page 1 3.6 cm 1/8” NPT , VCR8 3.1 cm VCR4 flange 1.9 cm Flange and Housing material: Stainless steel 304 Weight (901P with KF16): 170 g Climate category: IP40 Operating temperature: 0 to 40 Bakeout temperature (Power off): (1) Refer to Operation and Installation manual for Piezo accuracy details.
  • Page 2 Refer to Operation and Installation manual for calibration and adjustment recommendations. Install the 901P away from pumps and gas sources and where vibration is minimized to give the most representative pressure measurement. The 901P can be mounted in any orientation, without compromising accuracy and performance.
  • Page 3  Ensure a low impedance electrical connection between the 901P transducer body and the grounded vacuum system to shield the sensor from external electromagnetic sources. To comply with EN61326-1 immunity requirements, use a braided, shielded cable.
  • Page 4 Refer to Operation and installation manual for gas dependency data. US & ASIA: EUROPE: MKS Instruments, Inc., HPS™ MKS Denmark ApS Products, Inc., Ndr. Strandvej 119G 5330 Sterling Drive, Boulder, CO...

This manual is also suitable for:

100017411

Table of Contents