B1.2 Description of Parameters

Select the access number or letter, of any of the items in the Main Menu, followed by a CR (
sub-menu. It is not necessary for the parameter to be displayed to select it by number.
Note. The correct security level must be selected in
headings in this description or access notes against individual parameters.
Select the access number or letter of any item in a sub-menu, followed by a CR, to read the value or to change it as necessary.
(CR)s without an access code cycles through a menu continuously without accessing a parameter. All 'live' data displayed is
updated each second.
Main Menu
Read
1 >
Requires Level 2 access>
Disp
2 >
Login
3 >
Requires Level 2 access>
Requires Level 2 access>
Note. Access level selected is reset to Level 0 after a 'Quit' from Main Menu.
Sub-menus
1
Read Flow
1>
Flowrate in chosen units.
Flowrate as a percentage of range
Read %
2>
Accumulated total in forward totaliser *
Read Fwd
3>
Accumulated total in reverse totaliser *
Read Rev
4>
Net Total (= Forward minus Reverse) *
Read Net
5>
Cyclic display of active alarms.
Read Alm
6>
Read Vel
7>
True flow velocity in m/s, or ft/s if flow units are in
Ugal or ft^ 3.
Read Quit
Q>
Enter Q (CR) to return to Main Menu or (CR) to cycle around this menu.
* Resettable to zero if Tot ClrEn is set ('73' from Main Menu)
2
Disp Mode
1 > 1
Set single, double or multi-line display on terminal.
0 = Single line display.
1 = 2 line display for small displays (default).
2 = New line for each display update (e.g. for printers, data logging, etc.).
Set resolution of flow display. Enter number of decimal places required.
Disp Res
2 > 3
Enter Q (CR) to return to Main Menu, or (CR) to cycle around this menu.
Disp Quit
Q >
conversant with the operation of the menu system.
3
Shows current security level (0 = default). Enter password for level required.
Login En
1 > 0
'usee'
'engineer' = Default for Level 2
Login Key
2 >
Enter new password to replace existing level 1 word
.
Login Key
3 >
Enter new password to replace existing level 2 word
.
Enter Q (CR) to return to Main Menu or (CR) to cycle around this menu.
Login Quit
Q >
parameter below to access certain parameters. See
Login
Remarks
Caution. Do not attempt to modify passwords unless fully
= Default for Level 1
...APPENDIX B
etc), to access its associated
RETURN
17