Chapter 8 - 808-P2 Programming Instructions - Garnet SeeLevel Special 808-P2 Important Operator Information

Tank truck level gauge
Table of Contents

Advertisement

CHAPTER 8 - 808-P2 PROGRAMMING INSTRUCTIONS

T
he 808-P2 provides an interactive programming experience. When
the programming plug is connected to the gauge, the gauge display
will show "prog" within a couple of seconds. Do not start programming
the gauge until "prog" is shown. After the plug has been removed, the
gauge display will show "donE" for a moment.
NOTE: It is not possible to directly copy the calibration from an 808, 808i,
W
808A or old style 810 to an 808-P2. The calibration will have to be re-entered
using the procedure to calibrate a gauge from a table of calibration values.
Program the 808-P2 for the correct mode (1/3", 1/4", or 1/6"), alarm
configuration or check the software revision:
1. The 808-P2 display can be used with the 808, 810, or 908 bars, which
requires the installer to make sure that the display is programmed for
the correct mode so that it will operate correctly with the sender bar
used.
2. The 817-USB Truck Gauge Programmer is not needed for this
operation. Only a magnet is required to change the mode.
3. Disconnect the fiber from the display and make sure that no ambient
light is getting into the optical connector.
showing "no L" in order to set the mode.
4. Hold the magnet next to the display face by the "G" in Garnet.
5. Within a couple of seconds, the display will show the software revision,
for example 8.18. Continue to hold the magnet by the face.
6. After one second of showing the sofware revision, the display will
show "C1-3", "C1-4" or "C1-6" indicating the current mode that
the display is set for (the "C" means "current"). Continue to hold the
magnet by the face.
7. After 3 seconds of showing the current mode, the display will show
"P1-3" for 3 seconds, then it will show "P1-6" for three seconds,
then it will show "P1-4" for three seconds (the "P" means "program").
Removing the magnet during the time that "P1-3" is shown will
program the mode at 1/3", removing the magnet during the time that
"P1-6" is shown will program the mode at 1/6", and removing the
magnet during the time that "P1-4" is shown will program the mode
at 1/4". To confirm that the new mode has been stored in memory, the
display will show "Stor" for one second after removing the magnet.
(Some early models may not show the P1-4 mode; in this case use
the P1-6 mode if a ¼" resolution bar is being used. Also, some early
models may not show step 5 or step 8).