11. If wiring is used, route the wires into the display box using appropriate
water tight fittings and conduit. Connect the BLACK wire to ground,
the RED wire to a 12 volt clearance light circuit (this operates the LCD
back light), and the YELLOW alarm wire to the alarm circuit (if used).
The alarm wire completes a circuit to ground when active, so the other
end of the circuit needs provide power. The PURPLE automatic alarm
wire is connected to the negative side of a relay coil, with the positive
side connecting to +12 volts. The relay contacts control power to
the warning horn or light, this should be "PTO sensed" power. This
means that the power is only supplied to the warning device when the
PTO is engaged. The GREEN SpillStop wire goes to the compartment
terminal on the 815, or to the Yellow wire of the 815-UHP. The WHITE
switch wire goes to the white wire on the automatic alarm reset switch,
with the black switch wire going to ground. To program the alarms
and the SpillStop see the alarm programming section. Contact Garnet
for information concerning the connection of the GREEN/YELLOW
remote wire. Note that the GREEN/YELLOW wire may not be installed
on all displays
Wire Color
Green
Yellow
Purple
Black
Red
Green/Yellow
12. Inspect the display cap for casting flash, lightly sand or scrape off any
casting protrusions. Make sure that there is grease on the rubber
O-ring and snap on the display cap.
13. Verify gauge operation by lifting the float. Record the unit number,
calibration units, minimum and maximum readout values, and any alarm
points programmed in the IMPORTANT OPERATOR INFORMATION
area on the front page of the manual. The truck operator must be
given the manual upon delivery with all front page data filled in.
808-P2 Manual
Wiring Guide
Operation
815-UHP SpillStop signal line
Shutdown alarm output
Horn alarm output
Ground
+12VDC
SeeLeveL Access signal line
Page 17