Garnet SeeLevel Special 808-P2 Important Operator Information page 25

Tank truck level gauge
Table of Contents

Advertisement

8. Make sure that the fibre from the sender bar is connected to the
gauge display, and plug the programmer plug into the gauge display.
Press the BAR button. The INCHES display should show some inch
reading, if it shows "no L" or "bad L' check the fibre connection and
the bar mode (1/3 or 1/6 inch).
NOTE: The black fibre optic cable connector MUST be shaded from
W
direct sunlight. See the information in the Description of Keypad Buttons
section for further information.
9. Measure the distance from the bottom of the tank to the middle of the
float, this is the bottom reading. Use the OFFSET buttons to obtain
this reading on the CALIBRATION display. NOTE: The calibration offset
is carried over when memory locations are changed.
10. Press the PROG button to transfer the calibration to the gauge.
11. When the operation is complete, unplug the programmer from the
gauge and verify gauge operation.
Copy one 808-P2 gauge display to another (can also copy from an
808PA, 810P2, or an 810PS/810PS2):
1. Turn on the programmer.
2. Make sure the inch mode is correct.
3. Select a memory location with MEM LOC.
4. Plug the programmer plug into the gauge display to be copied from.
Press the COPY button to copy the gauge calibration into memory.
5. When the operation is complete, unplug the programmer plug from
the first gauge and plug it into the gauge display to be copied to. Press
the PROG button to transfer the calibration to the second gauge.
6. When the operation is complete, unplug the programmer from the
gauge and verify gauge operation.
Program an 808-P2 gauge display from a table of calibration values:
1. Obtain a table of inches versus volume
2. Turn on the programmer.
3. Make sure the inch mode is correct.
4. Select a memory location with MEM LOC.
5. Press the CLEAR MEM button to erase any previous calibration.
808-P2 Manual
Page 25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Seelevel special 808p2

Table of Contents