Garnet SeeLevel Special 808-P2 Important Operator Information page 21

Tank truck level gauge
Table of Contents

Advertisement

To set the density:
1. The display must be showing a valid reading in order to set the density.
If "no L" or some other error message is showing, repair or connect
the gauge before proceeding.
2. Press and hold the alarm reset button. After about 7 seconds the
display will show the current density setting, for example, "C .90"
indicates a current density setting of 0.90 which is the default. Release
the button at this point.
3. If no further action is taken, the display will revert to normal operation
after about 5 seconds with no change in the density setting. This is
useful if you just want to check the current density setting.
4. To change the density setting, press and release the button repeatedly
until the correct density is shown. This must be started before the
5 second time expires, otherwise start again at step 2. The "C" for
"current density" on the display will change to "P" for "Program
density" and the density will increase from the current setting in 0.05
increments for each button press. For example, if the current density
is 0.90, then the display will show "P .95", "P1.00", "P1.05", "P1.10",
"P1.15", "P1.20", then it will start over at "P .60", "P .65", and so on.
5. When the correct density is shown, stop pressing the button. After 5
seconds the display will show "Stor" for 2 seconds, indicating that the
new density value has been stored.
6. The display will then return to normal operation.
To program which float is being used:
1. Since the plastic and stainless steel floats have different buoyancies,
the display must be programmed with the type of float used so the
density correction will be accurate. This only needs to be done once
during installation.
2. The display must be showing a valid reading in order to program the
float type. If "no L" or some other error message is showing, repair
or connect the gauge before proceeding.
3. Press and hold the alarm reset button. After about 7 seconds the
display will show the current density setting, for example, "C .90"
indicates a current density setting of 0.90 which is the default.
Continue to hold down the button.
4. Put a magnet next to the display face by the "G" in Garnet, with the
hole in the magnet facing left and right, not up and down.
5. The display will change to "PL F" or "SS F" depending on whether
the display is currently programmed for a plastic or stainless steel
float. When this happens, remove the magnet and release the button.