October 2000
When correctly inserted, the top of the 201i server is on the left. See the
following diagram:
ATTENTION
6
Connect the low-profile right-angle SCSI connector on the NTRH3502 cable to
the SCSI connector on the 201i server faceplate.
7
Fasten the SCSI cable's drain wire to the top screw that previously held the
inner SCSI bracket in place.
8
Attach two ferrites from the NTRH3503 EMC kit to the SCSI cable.
Part 2: 201i Server Hardware Installation
Installing the server and connecting the peripherals
Do not push the 201i server into place against the backplane
yet.
All peripheral devices (monitor, keyboard, mouse, and SCSI
device) must be connected before the 201i server starts. If the
Option 11C Mini is connected to a power source, the 201i
server receives power and starts as soon as the 201i server is
locked into position in the cabinet.
G101588