MASK
INDEX
DESCRIPTION
Dab01
L1
Fans regulation type
Dab01
L1
Fans control mode
Dab02
L1
Minimum condensing setpoint
Dab02
L1
Maximum condensing setpoint
Dab03
L1
condensing setpoint
Dab04
L1
Fan can work only when at least one compressor work
Dab06
L1
Cond. - Regulation type (P - P+I - PID)
Dab06
L1
Cond. - Integral time
Dab14
L1
condensing neutral zone minimum complete activation time (neutral zone)
Dab14
L1
condensing neutral zone maximum complete activation time (neutral zone)
Dab15
L1
condensing neutral zone minimum complete deactivation time (neutral zone)
Dab15
L1
condensing neutral zone maximum complete deactivation time (neutral zone)
Dad05
L1
Enable floating condensing setpoint compensation
Dad06
L1
Floating condensing offset
Daf01
L1
Number of fans
Daf04
L1
condensing refrigerant type
Daf05
L1
Fans rotation type
Dag01
L1
Fans modulating device type
Dag02
L1
Fan inverter minimum voltage
Dag02
L1
Fan inverter maxiimum voltage
Dag02
L1
Fan inverter minimum activation
Dag02
L1
Fan inverter maxiimum activation
Dag13
L1
Speed-up procedure duration
Dab05
L1
Setup for fans regulation cutoff
Cae04
L1
Compressors alarm 1 delay
Cae04
L1
Alarm1 of compressor start delay
Cae04
L1
Compressor alarm 1 type(0.Auto 1.Manual)
Cae04
L1
Compressor alarm 1 priority (0=Light - 1=Serious)
Cae07
L1
Compressors alarm 2 delay
Cae07
L1
Alarm 2 of compressor start delay
Cae07
L1
Compressor alarm 2 type(0.Auto 1.Manual)
Cae07
L1
Compressor alarm 2 priority (0=Light - 1=Serious)
Cae10
L1
Compressors alarm 3 delay
Cae10
L1
Alarm 3 of compressor start delay
Cae10
L1
Compressor alarm 3 type(0.Auto 1.Manual)
Cae10
L1
Compressor alarm 3 priority (0=Light - 1=Serious)
Cae13
L1
Compressors alarm 4 delay
Cae13
L1
Alarm 4 of compressor start delay
Cae13
L1
Compressor alarm 4 type(0.Auto 1.Manual)
Cae13
L1
Compressor alarm 4 priority (0=Light - 1=Serious)
Cae16
L1
Compressors alarm 5 delay
Cae16
L1
Alarm 5 of compressor start delay
Cae16
L1
Compressor alarm 5 type(0.Auto 1.Manual)
Cae16
L1
Compressor alarm 5 priority (0=Light - 1=Serious)
Cae19
L1
Compressors alarm 6 delay
Cae19
L1
Alarm 6 of compressor start delay
Cae19
L1
Compressor alarm 6 type(0.Auto 1.Manual)
Cae19
L1
Compressor alarm 6 priority (0=Light - 1=Serious)
Copyright HPL March 2021
VALUE
UOM
TYPE
0
PROPORTIONAL BAND
1
TEMPERATURE
18
°C
30
°C
26
°C
1
YES
0
PROPORTIONAL
0
sec
5
sec
30
sec
10
sec
60
sec
1
°C
3
°C
1
10
1
FIFO
1
0-10V INVERTER-EC FANS
0
V
100
V
5
kW
100
kW
5
sec
20
°C/barg
0
sec
0
sec
0
AUTO
1
SERIOUS
0
sec
0
sec
0
AUTO
1
SERIOUS
0
sec
0
sec
0
AUTO
1
SERIOUS
0
sec
0
sec
0
AUTO
1
SERIOUS
0
sec
0
sec
0
AUTO
1
SERIOUS
0
sec
0
sec
0
AUTO
1
SERIOUS
Page 2 of 16
CHANNEL
MIN
MAX
OFFSET
Page 147 of 179
FULL CAREL PARAMETERS LIST
HPL
ADJUSTED
Last Printed: 05/02/2020
P41135 Rev 03