Daikin GCU2020PXB1 Installation, Commissioning And Maintenance Manual page 106

Table of Contents

Advertisement

Mask index
Display description
Ab05 (display
UserSetp.
only)
ActualSetp.
Diff .
Ab06 (display
UserSetp.
only)
ActualSetp.
Dead zone
Incr.Diff .
Decr.Diff .
Ab07 (display
UserSetp.
only)
ActualSetp.
Diff .
Ab08 (display
UserSetp.
only)
ActualSetp.
Dead zone
Incr.Diff .
Decr.Diff .
Ab12
Setpoint
Ab13
Setpoint
Ab14
Setpoint
Ab15
Setpoint
Ac01
Status
---
Ac02
L1:
L2:
---
---
Ac03
Enable unit On/Off
from digital input
From supervisor
Due to black out
Ac04
Delay unit startup after
blackout
Ac06
Enable unit On/Off
from digital input
From supervisor
Due to black out
Ac07
Unit startup delay after
blackout
Mask index
Display description
B.Inp./Out.
The I/Os depend on the confi guration selected, the following are only examples. See Appendix A.1 for the complete list and position of available I/Os.
Baa02
DI
Status (display only)
Logic
Function (display only)
...
...
Baacf
DI
Status
Logic
Function
...
...
Bab01
---
---
--- (display only)
Max limit
Min limit
Calibrat.
Bab63
---
---
--- (display only)
Max limit
Min limit
Calibrat.
Copyright HPL March 2021
Description
Setpoint set by the user for gas cooler regulation under pressure, proportional regulation
(line 1)
Actual setpoint for gas cooler regulation under pressure, proportional regulation (with
compensations applied, line 1)
Gas cooler regulation under pressure diff erential, proportional regulation (line 1)
Setpoint set by the user for gas cooler regulation under pressure, proportional regulation
(line 1)
Actual setpoint for gas cooler regulation under pressure, proportional regulation (with
compensations applied, line 1)
Dead zone for gas cooler regulation under pressure (line 1)
Increase diff erential for gas cooler regulation under pressure, regulation in dead zone
(line 1)
Decrease diff erential for gas cooler regulation under pressure, regulation in dead zone
(line 1)
Setpoint set by the user for condensing regulation under pressure, proportional regulation
(line 2)
Actual setpoint for condensing regulation under pressure, proportional regulation (with
compensations applied, line 2)
Condensing regulation under pressure diff erential, proportional regulation (line 2)
Setpoint set by the user for condensing regulation under pressure, proportional regulation
(line 2)
Actual setpoint for condensing regulation under pressure, proportional regulation (with
compensations applied, line 2)
Dead zone for condensing regulation under pressure (line 1)
Increase diff erential for condensing regulation under pressure, regulation in dead zone
(line 2)
Decrease diff erential for condensing regulation under pressure, regulation in dead zone
(line 2)
Setpoint without compensation (suction line 1)
Setpoint without compensation (gas cooler line 1)
Setpoint without compensation (suction line 2)
Setpoint without compensation (condens. line 2)
Unit status (display only)
On-off from keypad (line 1)
Unit status (display only)
On-off from keypad (line 1)
On-off from keypad (line 2)
Enable unit On/Off from digital input (line 1)
Enable on-off from supervisor (line 1)
Enable on-off due to black out (line 1)
Delay unit startup after blackout (line 1)
Enable unit On/Off from digital input (line 2)
Enable on-off from supervisor (line 2)
Enable on-off due to black out (line 2)
Unit startup delay after blackout (line 2)
Description
Alarm 1 compressor 1 DI position(line 1)
Status Alarm 1 compressor 1 DI (line 1)
Logic alarm 1 compressor 1 DI (line 1)
Alarm 1 compressor 1 function status (line 1)
...
Heat recovery from digital input DI position (line 1)
Heat recovery from digital input DI status (line 1)
Heat recovery from digital input DI logic (line 1)
Heat recovery from digital input function status (line 1)
...
Suction pressure probe position (Line 1)
Suction pressure probe type (Line 1)
Suction pressure value (line 1)
Suction pressure maximum value (line 1)
Suction pressure minimum value (line 1)
Suction pressure probe calibration (Line 1)
Common oil receiver pressure probe position (line 1)
Common oil receiver pressure probe type (line 1)
Common oil receiver pressure value (line 1)
Maximum common oil receiver pressure value (line 1)
Minimum common oil receiver pressure value (line 1)
Common oil receiver pressure probe calibration (line 1)
57
Page 106 of 179
Def.
U. of M.
Values
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
---
...
...(**)
26.0 barg
...
...(**)
12.0 °C
...
...(**)
12.0 barg
...
...(**)
12.0 barg
...
...(**)
OFF from
---
Wait...
keypad
Unit ON
OFF from Alarm
OFF from blackout
OFF from BMS
OFF from default
OFF from DIN
OFF from keypad
Manual Funct. work
Prevent from HP
OFF
---
OFF | ON
OFF da
---
... (see Ac01 above)
tastiera
OFF
---
OFF | ON
OFF
---
OFF | ON
NO
---
NO | YES
NO
---
NO | YES
NO
---
NO | YES
0
s
0...999
NO
---
NO | YES
NO
---
NO | YES
NO
---
NO | YES
0
s
0...999
Def.
U. of M.
Values
03
---
---, 01...18,
U1...U10 (****)
---
---
Closed | Open
NC
---
NC | NO
---
---
Not active | Active
...
...
...
---
---
--- | 01...18 |
U1...U10 (****)
---
---
Closed | Open
NC
---
NC | NO
---
---
Not active | Active
...
...
...
B1
---
---, U1...U10 (****)
4...20mA
---
---
0-1V
0-10V
4...20mA
0-5V
---
...
...(**)
44.8 barg
...
...(**)
0.0 barg
...
...(**)
0.0 barg
...
...(**)
---
---
U1...U10 (****)
4...20mA
---
---- | 0-1V | 0-10V
4...20mA | 0-5V
---
...
...(**)
44.8 barg
...
...(**)
0.0 barg
...
...(**)
0.0 barg
...
...(**)
P41135 Rev 03
pRack PR300T +0300018EN rel. 1.5 - 02.05.2017
ENG
Tab. 7.b

Advertisement

Table of Contents
loading

This manual is also suitable for:

Esie20-02

Table of Contents