Table 165: Programmable
V09 software
Button
and earlier
Data Point Slot
Operator
# (1-6)
Data Point Min
Operator
(1-6)
Data Point Max
Operator
(1-6)
Table 166: Navigation
Button
Home
Trending
Slot Numbers
Triggers
Model YK Style H Centrifugal Liquid Chillers with OptiView Control Center
V10 and later
with YORK
Description
Chiller Access
Manager
Use the Select key as described above and enter the Slot Number from
the Common Slots Screen or Master Slot Number List of the desired
Standard
parameter to be trended. The selected parameter description will be
displayed for the Data Point. Setting this Slot Number to zero will disable
trending for that particular Data Point. Any or all points can be disabled.
Only displayed if the Associated Slot Number is not zero. This is the
minimum value displayed for the Y-axis. Selecting a parameter for a Data
Point sets this to the default value, which is the lowest value allowed
for that parameter. It can be changed to a value that provides a more
appropriate resolution for the parameter being monitored. To change,
Standard
use the Select key as described above and enter the desired value.
The value must always be set to a value less than the Data Point Max.
Otherwise, a red graph is displayed on the Trend screen with the words
TREND MAX MUST BE > TREND MIN. If the parameter selected for this
data point is a digital type (on/off), this value must be set to zero (0). Zero
indicates the OFF state.
Only displayed if the associated Slot Number is not zero. This is the
maximum value displayed for the Y-axis. Selecting a parameter for a Data
Point sets this to the default value, which is the highest value allowed
for that parameter. It can be changed to a value that provides a more
appropriate resolution for the parameter being monitored. To change,
use the Select key as described above and enter the desired value. The
value must always be set to a value greater than the Data Point Min.
Otherwise, a red graph is displayed on the Trend screen with the words
Standard
TREND MAX MUST BE > TREND MIN.
There are 20 Y-axis divisions. If a min-max span is selected that is not
evenly divided by 20, the program will automatically select the next
higher max value that makes the span evenly divided by 20 (if compressor
application is other than P). For example, if 0.0 is selected as the min and
69.0 is selected as the max, the program will insert 70.0 as the max value.
If the parameter selected for this data point is a digital type (on/off), this
value must be set to one (1). One indicates the on state.
Description
Returns user to Home Screen.
Returns user to Trend Screen.
Causes a jump to a subscreen that lists the Slot Numbers of the most commonly
monitored parameters. The desired parameters to be plotted are selected from this
screen.
Causes a jump to the Advanced Trend Setup Screen, where the start/stop Triggers can
be setup. Only displayed if triggered has been selected as Chart Type.