BladeRight2
Enter offset mode, Select BladeRight2, press the ENTER button to confirm, the present position will
blink on the display, use the UP/DOWN button to offset the value from -128 to 127, press the
ENTER button to store. Press the MENU button to exit.

6. Control By Universal DMX Controller

6.1 DMX512 Connection

1. At last unit, the DMX cable has to be terminated with a terminator. Solder a 120-ohm 1/4W
resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output
of the last unit.
2. Connect the unit together in a "daisy chain" by XLR plug cable from the output of the unit to
the input of the next unit. The cable cannot be branched or split to a "Y" cable. DMX 512 is a very
high-speed signal. Inadequate or damaged cables, soldered joints or corroded connectors can easily
distort the signal and shut down the system.
3. The DMX output and input connectors are pass-through to maintain the DMX circuit, when one
of the units' power is disconnected.
25A