Brother BE-0901E-AC-PC Instruction Manual page 232

Pc control type
Table of Contents

Advertisement

Chapter 11 Error code list
Code
E-CB
Spindle rotation speed error
E-CD
Speed command can not be received.
E-E3
Cooling fan motor stop.
Over-run error during interfacing to main PCB
E-E5
CPU
Framing error during interfacing to main PCB
E-E6
CPU
Parity error during interfacing to main PCB
E-E7
CPU
Receiving time up error during interfacing to
E-E8
main PCB CPU
Send/Receive inconsistent error during
E-E9
interfacing to main PCB CPU
ACK code receiving error during interfacing to
E-EA
main PCB CPU
Send/Receive ID code error during interfacing
E-EB
to main PCB CPU
Send data checksum error during interfacing to
E-EC
main PCB CPU
Data empty error during interfacing to main
E-ED
PCB CPU
E-EE
Receiving error on interface
E-F1
Send time up error
E-F2
Request-to-waiting time up error
E-F3
Request-to-recive time up error
E-F4
Receive command error
E-F5
NACK code receiving error
Data requested for needle position can not be
E-F6
returned.
E-F7
It is not receive command for the request one.
E-F8
PRE code error
E-F9
No applicable command
E-FA
Interface receive data sum check error
E-FB
Send time up error
E-FF
No status is returned from main shaft CPU.
11-4
Error
BE-0901E-AC-PC• BE-1201B-AC-PC
Press the
to cancel the error and press the
same error occurs again, there is a possibility that the spindle is
overloaded..
Turn the power off and on once. If the same error occurs again,
the main PCB is faulty.
Turn off the power and check the fan harness. Turn on the
power again. If the same error occurs again, the fan or the main
PCB is faulty.
This is not usually displayed.
Measures
If the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-1201b-ac-pcBe-0901e pcBe-1201b-ac