Maintenance
e) Select the Technical Key Operator icon. The Technical Key Operator feature
displays.
f) Select the CRU item that corresponds with the newly-replaced component.
g) Select Reset Current Value. The system resets the HFSI to 0.
10. Exit administrator mode by pressing the Log In/Out button on the Control Panel.
When prompted, select Logout.

Removing the Fuser Module

Warning
You must wait 50 minutes to allow the Fuser Assembly to cool down to a safe temperature
before performing these tasks.
Caution
When pulling out the Transfer Drawer to the Service position, do not attempt to pull the
drawer further out towards you. Pulling the drawer further out will disengage it from the
rails resulting in damage to the drawer and possible injury.
Caution
Make sure the press is powered off. Do not perform this replacement procedure with
the power on or electrical power supplied to the system. Allow the fuser to cool down
for 50 minutes before performing any maintenance.
The reasons for removing and/or replacing the Fuser Module components include:
Replace the entire Fuser Module, which includes the components listed below, after
650,000 prints or if damaged:
- Belt Module (choose up to 3 different modules available for fuser width change;
at installation, one standard fuser is provided)
- Pressure Roll
- Stripper Finger Assembly
- Pressure Roll Cleaning Pad
Experiencing image quality issues or damage in the Fuser area
Accessing other components within the Fuser Assembly area for maintenance
if you run a mixed type of job within your workflow and switched from running 11
inch paper to an oversized paper, this could cause an edgewear defect. To resolve,
you can exchange and use another Fuser Belt Module, up to 3 different widths (for
example, 11 inch/A4 width, 12 inch width, or a custom size)
If you exchange the fuser type, you will need to also connect the associated jumper to
the assembly to identify the Fuser Width ID being used:
Connecting and
Changing the Fuser Width ID
Prerequisite: Prepare Your Tools
5-20