Electrical Operation; Component Function - Vulcan-Hart VG30 Service Manual

Gas braising pans (30 & 40 gallon)
Table of Contents

Advertisement

COMPONENT FUNCTION

Temperature Controller . . . . Monitors thermocouple input (type E) and regulates braising pan temperature. An
Transformer . . . . . . . . . . . . . Supplies 24VAC for heating circuit. If motorized pan lift option is installed,
ON/OFF Switch . . . . . . . . . . Controls 24VAC to the gas heating circuit. If motorized pan lift option is installed,
Power On Light (Amber) . . . Indicates on/off switch is turned on.
Heat Light (Red) . . . . . . . . . . Indicates temperature controller is calling for heat and pan is down.
Pan Position/
Down Limit Switch . . . . . . . . N.O. contacts function as pan position switch to power the gas heating circuit
Ignition Control Module . . . Controls and monitors gas heating. Energizes pilot valve coil to supply gas to
Ignitor/Flame Sense
Electrode . . . . . . . . . . . . . . . . Ignites pilot burner and senses the presence of a flame. The Igniter/Flame Sense
Gas Combination
Valve . . . . . . . . . . . . . . . . . . . Allows gas flow to the pilot burner when pilot valve coil is energized; and gas flow
DC Motor Controller . . . . . . . Controls DC lift motor operation for raising & lowering of the pan, and provides
DC Lift Motor . . . . . . . . . . . . . Operates gear reducer to raise or lower the pan. When the correct voltage
Lid Switch . . . . . . . . . . . . . . . Supplies 24VAC power to lift control switch. Used to ensure lid is open before pan
Lift Control Switch
(Momentary On/Off/On) . . . . Energizes K1 relay coil thru up limit switch contacts (N.C.) to raise the pan.
Up Limit Switch . . . . . . . . . . Removes power from K1 relay coil when pan reaches full tilt (pan travel stops).
Pan Position/
Down Limit Switch . . . . . . . . N.C. contacts function as down limit switch to remove power from K2 relay coil
K1 "Up" Relay (3PDT) . . . . . Supplies power to motorized lift circuit to raise the pan when 24VAC coil is
K2 "Down" Relay (3PDT) . . . Supplies power to motorized lift circuit to lower the pan when 24VAC coil is
GAS BRAISING PANS - ELECTRICAL OPERATION

ELECTRICAL OPERATION

BRAISING PAN CONTROLS
external set point potentiometer is used for temperature adjustments.
supplies 24VAC for lift control circuit.
controls power to lift circuit.
when pan is down. Removes power from gas heating circuit when pan is raised.
The N.C. contacts are used for the down limit switch (motorized lift option only).
pilot, generates spark to light gas at the pilot, monitors the presence of flame and
energizes the main valve coil upon a call for heat.
is a component of the pilot burner.
to the runner tube & main burners when main valve coil is energized. Also,
regulates gas manifold pressure.
MOTORIZED PAN LIFT OPTION CONTROLS
motor acceleration control each time the controller is powered. The controller
outputs approximately 90VDC to power the motor.
polarity is applied thru K1 contacts, motor rotates CW to raise pan. When reverse
voltage polarity is applied thru K2 contacts, motor rotates CCW to lower the pan.
can be raised.
Energizes K2 relay coil thru down limit switch contacts (N.C.) to lower the pan.
The switch positions are: Center neutral (starting) position off; Momentary on -
lower pan; Momentary on - raise pan.
when pan is lowered to the down position (pan travel stops). The N.O. contacts
are used for the pan position switch.
energized.
energized by the lift control switch. The voltage polarity to the DC motor is
reversed thru K2 contacts to turn motor CCW and lower the pan.