4.

trOuble shOOting

See also 2.7. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.
• Check water circulation.
• Check that there is enough free space behind the machine for cooling air
circulation.
error code err 5 on the KempArc panel
• Check the liquid hoses for damages.
• Remove any hose blockages.
• Check water circulation, add liquid if needed.
For further information and assistance, contact your nearest Kemppi service
workshop.
5.

teChniCAl DAtA

Cooling unit KempArc™ Cool 10
Connection voltage
Connection capacity
Cooling power
Start pressure, max.
Cooling liquid
Reservoir volume
Overall dimension:
Weight
Operating temperature range
Storage temperature range
Degree of protection
The products meet the conformity requirements of CE-marking.
24 V DC
100 % ED
50 W
1 kW
450 kPa
20 % - 40 % etanol/water
ca. 3 l
length
570 mm
width
230 mm
height
280 mm
11 kg
-20 ... +40 °C
-40 ... +60 °C
IP 23 S
EN
11