INSTALLATION

5

SPECIFICATIONS

Width: 25 ¾"
Height: 32 5/8"
Depth: 23 7/8"
Weight: 275 lbs.
Flue size: 3" or 4"
Hopper Capacity: Up to 140 lbs.
(This can vary widely depending on pellet
size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 55,000
Approved installations: mobile home, alcove,
conventional

PREPARATION

Factory packaging must be removed, and
FIGURE 1
some minor assembly work is required prior
to installation. Access to the rear of the stove
is necessary.
NOTE: Normally, your dealer will perform
these functions.

CLEARANCES

The Big E has been tested and listed for
installation in residential and mobile homes.
FLOOR PROTECTION: Freestanding
installations, minimum 30" wide by 32" deep.
The stove must be placed on a continuous
(grouted joints) noncombustible material such
as ceramic tile, cement board, brick, 3/8"
millboard or equivalent, or other approved or
listed material suited for floor protection.
THE MATERIAL(S) USED MUST HAVE, OR
COMBINE TO HAVE, A MINIMUM
INSULATIVE RATING OF 'R1'.
NOTE: ceramic tile, or any tile, requires a
continuous sheet beneath to prevent the
possibility of embers falling through to the
FLOOR PROTECTION
combustible floor if cracks or separation
(MINIMUM 30" W X 32" D)
should occur in the finished surface, this
would include floor protection for Built-in
raised hearths. Check local codes for
FIGURE 2
approved alternatives.
Clearances are measured from the sides,
back and face (door opening) or stove body
(refer to fig. 2).
DO NOT USE MAKESHIFT MATERIALS OR
COMPROMISES IN THE INSTALLATION
OF THIS UNIT.
INSTALL VENT WITH CLEARANCES
SPECIFIED BY THE VENT
MANUFACTURER.