Internal Connections For Tethered Cable; Technical Specifications - newmotion Business Pro 2.2 Installation Manual

Table of Contents

Advertisement

3.2.1. Internal connections for tethered cable

1. Earthing tethered cable
2. Cable clamp
3. Tethered cable inlet
4. Tethered cable connection. Keep the same
order as the connection under contactor
L1 = portal 1
L2 = portal 2
L3 = portal 5
Neutral = portal 7
3.3.
Technical specifications
Maximum of Business Pro charge points in one
group
Maximum of Business Lite charge points per
group
Models allowed in group
Serial number format Business Pro (Cable)
Serial number format Business Lite (Cable)
Maximum charge capacity
Factory configured charge capacity
Fail-safe current during data connection failure
Electric safety category
DC fault current protection
Dimensions (H × W × D)
Weight
IEC-62262 IK code (robustness)
IEC-60529 IP code (protection class)
Installation manual – NewMotion Business Pro & Lite 2.1 / 2.2 - 091NMEN13
7
6
5
4
3
1
Daisy chain configuration: 15
Star configuration: 40
Business Pro & Lite 2.0 / 2.1 / 2.2
09 1 _ _ _ _ _
08 1 _ _ _ _ _
1-phase 32 A (7,4 kW)*
3-phase 32 A (22 kW)*
1-phase 16 A (3,7 kW)**
3-phase 16 A (11 kW)**
8 A per phase
Class I
Built-in 6 mA fault current protection (≤ 10 sec.)
503.5 × 200 × 137 mm
± 4.0 kg
IK10
IP54 (for indoor and outdoor use)
2
3
5. DC fault detection module
6. Connection DC fault detection module
7. Connector for communication with the car to
red wire
1
8
EN