Power Fist 8167561 User Manual

Power Fist 8167561 User Manual

Chemical resistant plastic rotary pump
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

V 2.0
Please read and understand all instructions before use.
Retain this manual for future reference.
Chemical
Resistant Plastic
Rotary Pump
User Manual
8167561

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8167561 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Power Fist 8167561

  • Page 1 V 2.0 8167561 Chemical Resistant Plastic Rotary Pump User Manual Please read and understand all instructions before use. Retain this manual for future reference.
  • Page 3: Important Safety Precautions

    V 2.0 8167561 Chemical Resistant Plastic Rotary Pump FEATURES • Plastic construction, allows use with a vast range of media. • Fits 15 to 55 gallon (50 to 205 litres) drums. • Dispenses 5 litres (1.30 gal.) per 20 turns •...
  • Page 4: Operation

    V 2.0 Chemical Resistant Plastic Rotary Pump 8167561 OPERATION PARTS IDENTIFICATION 1. Pump Body 2. Pump Handle (2 piece – Crank & Handle with nut) 3. Bung Nut with 2: threads (2 piece) 4. Discharge Spout (2 piece construction) 5. Suction Tube (3 piece construction) WETTED COMPONENTS: Polyethylene, Polypropylene, Stainless Steel 316, Ryton &...
  • Page 5 8167561 Chemical Resistant Plastic Rotary Pump V 2.0 3. Assemble the suction tube parts, depending upon the drum size on which the pump is to be installed. The suction tube part with the strainer may be connected directly onto the pump inlet or assembled with one extension or both extensions, depending upon the drum size.
  • Page 6 V 2.0 Chemical Resistant Plastic Rotary Pump 8167561 PRIMING 7. Take an empty container and place it below the discharge spout. Start to rotate the pump handle. Within a maximum of 7 rotations, the pump will be primed and will start dispensing media. In a rare case, where the pump does not get primed, the same can be done by reversing the outlet discharge spout on the pump and pouring about 30 ml of any oil into the outlet and turning the pump handle about seven rotations.
  • Page 7: Compatibility Chart

    8167561 Chemical Resistant Plastic Rotary Pump V 2.0 COMPATIBILITY CHART Liquid Compatibility Liquid Compatibility Acetaldeyde aq. Hydrobromic acid aq. Acetic acid aq. Hydrogen peroxide aq. Acetone Hydrogen sulphide aq. Aluminum chloride aq. Isopropyl Alcohol Aluminum sulphate aq. Kerosene Ammonia gas Lacquer Ammonium chloride aq.
  • Page 8: Troubleshooting

    V 2.0 Chemical Resistant Plastic Rotary Pump 8167561 TROUBLE SHOOTING Problem Cause Remedy Pump does not dispense fluid Pump not able to create adequate suction Prime pump. Follow step 7 in the INSTALLATION section Pump is drawing in air, instead of fluid...
  • Page 9 V 2.0 8167561 Pompe rotative en plastique à l’épreuve des produits chimiques Manuel du propriétaire Vous devez lire et comprendre toutes les instructions avant d'utiliser l'appareil. Conservez ce manuel afin de pouvoir le consulter plus tard.
  • Page 11: Caractéristiques

    V 2.0 8167561 Pompe rotative en plastique à l’épreuve des produits chimiques CARACTÉRISTIQUES • La construction en plastique permet d’utiliser la pompe avec une vaste gamme de produits. • Convient aux barils de 50 à 205 litres (15 à 55 gallons).
  • Page 12: Identification Des Pièces

    V 2.0 Pompe rotative en plastique à l'épreuve des produits chimiques 8167561 UTILISATION IDENTIFICATION DES PIÈCES Goulotte de 1. Corps de la pompe décharge 2. Poignée de la pompe Orifice de refoulement (2 pièces – Manivelle et poignée avec écrou) de la pompe Arbre à...
  • Page 13 8167561 Pompe rotative en plastique à l'épreuve des produits chimiques V 2.0 2. Fixez la poignée de la pompe sur la manivelle et raccordez la manivelle au vilebrequin sur le corps de la pompe. Fixez le raccord à l’aide du boulon compris dans l’ensemble.
  • Page 14 V 2.0 Pompe rotative en plastique à l'épreuve des produits chimiques 8167561 Préparation PRÉPARATION 7. Prenez un contenant vide et placez-le sous la goulotte de décharge. Commencez à tourner la poignée de la pompe. Avec un maximum de 7 rotations, la pompe sera prête et le produit commencera à s’écouler. Dans un rare cas où...
  • Page 15 8167561 Pompe rotative en plastique à l'épreuve des produits chimiques V 2.0 TABLEAU DE COMPATIBILITÉ Liquide Compatibilité Liquide Compatibilité Acétaldéhyde aqueux Acide bromhydrique aqueux Acide acétique aqueux Peroxyde d’hydrogène aqueux Acétone Sulfure d’hydrogène aqueux Chlorure d’aluminium aqueux Alcool isopropylique Sulfate d’aluminium aqueux Kérosène...
  • Page 16: Dépannage

    V 2.0 Pompe rotative en plastique à l'épreuve des produits chimiques 8167561 DÉPANNAGE Problème Cause Solution La pompe ne produit pas une succion Préparez la pompe. Suivez l’étape 7 de la La pompe ne distribue aucun liquide. suffisante. section INSTALLATION.

Table of Contents