Using The Controller; Parameter Ranges - Airstream TC4-2N6F User Manual

Combined ventilation control
Table of Contents

Advertisement

Parameter Ranges

PARAMETER
TEMPERATURE
SET POINT
STAGE 1 FANS
STAGE 2 FANS
CURTAINS
STAGE 3 & 5 FANS
MIST
HEATERS
Room set point
Outside set point
Minimum speed
Time on
Time off
Band width
Minimum speed
Differential
Time on
Time off
Dead band
Differential 3 and 5 0.5° to 20.0°F (0.3° to 11.1°C)
Time on
Time off
Differential
Differential
Offset
ADJUSTMENT RANGE
-40.0° to 99.9°F (-40° to 37.7°C)
-40.0° to 99.9°F (-40° to 37.7°C)
10 to 100% of the full speed of
the fans
0 to 900 seconds, by increments
of 15 seconds
0 to 900 seconds, by increments
of 15 seconds
0.5° to 20.0°F (0.3° to 11.1°C)
10 to 100% of the full speed of
the fans
0.5° to 20.0°F (0.3° to 11.1°C)
1 to 900 seconds, by increments
of 1 second
1 to 900 seconds, by increments
of 1 second
0.5° to 20.0°F (0.3° to 11.1°C)
1 to 60 minutes, by increments
of 1 minute
0 to 60 minutes, by increments
of 1 minute
0.5° to 20.0°F (0.3° to 11.1°C)
1.0° or 2.0°F (0.6° or 1.1°C)
1.0° or 2.0°F (0.6° or 1.1°C)