Combined ventilation control
Table of Contents

Advertisement

1
Digital display
Displays the parameters shown around the parameter selection knob.
2
Stage 1 and 2 pilot light
Flashes when the stage 1 fans are on. Turns on when the stage 2
fans are on.
3
Curtains A pilot light
Flashes when the zone A curtains are closing. Turns on when the
zone A curtains are opening.
4
Curtains B pilot light
Flashes when the zone B curtains are closing. Turns on when the
zone B curtains are opening.
5
Stage 3 - 5 pilot light
Flashes when the stage 3 fans are on. Turns on when the stage 5
fans are on.
6
Heater-mist pilot light
Flashes when the mist units are on. Turns on when the heaters are on.
7
Temperature curve pilot light
Turns on when the temperature curve is activated and flashes when
both the temperature and minimum speed curves are activated.
Defective probe pilot light
8
Turns on when a probe is defective.
Locked parameter pilot light
9
Turns on when the parameters are locked.
Push-button
10
Used to access the various adjustments.
Parameter selection knob
11
Used to select a parameter.
Adjustment knob
12
Used to adjust the value of a selected parameter.
8