MASTER BOX
TC4-2N6F Supply: - 115/230 VAC (-18%,+8%), 60 Hz, overload and
overvoltage protection fuse F6-1A fast blow.
T50-2N6F Supply: - 115/230 VAC (-18%,+8%), 50 Hz, overload and
overvoltage protection fuse F6-1A fast blow.
- 12 VDC for AC back-up supply; can activate Stage 3, Stage 5 as
well as curtains, mist and heaters if supplied with DC back-up voltage.
SLAVE BOX NO.1
Supply: - 115/230 VAC (-18%,+8%), 60 Hz, overload and overvoltage
protection fuse F5-1A fast blow.
- 12 VDC for AC back-up supply
Stage 1: Variable output, 60 Hz, 10A FAN (1/2HP/15VAC)/(1.5HP/230VAC),
fuse F1-15A slow blow.
Stage 2: Variable output, 60 Hz, 10A FAN (1/2HP/15VAC)/(1.5HP/230VAC),
fuse F2-15A slow blow.
SLAVE BOX NO.2
Supply: - 115/230 VAC (-18%,+8%), 60 Hz, overload and overvoltage
protection fuse F6-1A fast blow.
- 12 VDC for AC back-up supply; can activate Stage 3, Stage 5 as
well as Zone A curtains if supplied with DC back-up voltage.
Zone A curtains: OPEN-CLOSE output, 115/230 VAC, 60 Hz, 30VDC, 5A
winch output, fuse F1-5A slow blow.
Stage 3: ON-OFF output, 115/230 VAC, 60 Hz, 30VDC, 6A FAN, 10A RES,
fuse F3-10A slow blow.
Stage 5: ON-OFF output, 115/230 VAC, 60 Hz, 30VDC, 6A FAN, 10A RES,
fuse F4-10A slow blow.