TO ADJUST THE HEATER OFFSET
The heater offset can be adjusted to 1°F(0.6°C) or 2°F(1.1°C):
Set switch # 6 to ON to adjust the
heater offset to 1°F (0.6°C).
Set switch # 6 to OFF to adjust the
heater offset to 2°F (1.1°C).

Locking the Parameters

L
ocking the parameters prevents accidental or unauthorized modification
of the parameter settings. When the parameters are locked, only the room
set point and the points of the temperature curve (if the temperature curve is
deactivated), as well as the stage 1 minimum speed (as long as the
minimum speed curve is deactivated) can be modified. All other settings
can not be modified.
TO LOCK OR UNLOCK THE PARAMETERS
Set switch # 1 to ON to lock the parameters.
Set switch # 1 to OFF to unlock the parameters.
FACTORY SETTING: When the controller is shipped from the factory,
switch # 1 is set to OFF (the parameters are unlocked).